Rationale behind motion preservation devices is to eliminate the accelerated adjacent-level effects (ALE) associated with spinal fusion. We evaluated multidirectional flexibilities and ALEs of StabilimaxNZ® and simulated fusion applied to a decompressed spine. StabilimaxNZ® was applied at L4–L5 after creating a decompression (laminectomy of L4 plus bilateral medial facetectomy at L4–L5). Multidirectional Flexibility and Hybrid tests were performed on six fresh cadaveric human specimens (T12–S1). Decompression increased average flexion–extension rotation to 124.0% of the intact. StabilimaxNZ® and simulated fusion decreased the motion to 62.4 and 23.8% of intact, respectively. In lateral bending, corresponding increase was 121.6% and decreases were 57.5 and 11.9%. In torsion, corresponding increase was 132.7%, and decreases were 36.3% for fusion, and none for StabilimaxNZ® ALE was defined as percentage increase over the intact. The ALE at L3–4 was 15.3% for StabilimaxNZ® versus 33.4% for fusion, while at L5–S1 the ALE were 5.0% vs. 11.3%, respectively. In lateral bending, the corresponding ALE values were 3.0% vs. 19.1%, and 11.3% vs. 35.8%, respectively. In torsion, the corresponding values were 3.7% vs. 20.6%, and 4.0% vs. 33.5%, respectively. In conclusion, this in vitro study using Flexibility and Hybrid test methods showed that StabilimaxNZ® stabilized the decompressed spinal level effectively in sagittal and frontal planes, while allowing a good portion of the normal rotation, and concurrently it did not produce significant ALEs as compared to the fusion. However, it did not stabilize the decompressed specimen in torsion.
机译:运动保存设备背后的原理是消除与脊柱融合相关的加速邻近水平效应(ALE)。我们评估了StabilimaxNZ®的多向柔韧性和ALE,并对应用于减压脊柱的模拟融合进行了评估。减压后(L4椎板切除加L4–L5双侧内侧小平面切除术)施用于StabilimaxNZ®。在六个新鲜的尸体人体标本(T12–S1)上进行了多向灵活性和混合测试。减压使平均屈伸旋转增加到完整的124.0%。 StabilimaxNZ®和模拟融合分别将运动降低至完整的62.4和23.8%。在横向弯曲中,相应的增加为121.6%,减少为57.5和11.9%。扭转时,融合的相应增加为132.7%,融合的减少为36.3%,StabilimaxNZ®ALE没有定义为相对于完整的增加百分比。 StabilimaxNZ®的L3–4的ALE为15.3%,而融合的为33.4%,而L5–S1的ALE分别为5.0%和11.3%。在横向弯曲中,相应的ALE值分别为3.0%对19.1%和11.3%对35.8%。在扭转中,相应的值分别为3.7%和20.6%,以及4.0%和33.5%。总之,这项使用灵活性和混合测试方法的体外研究表明,StabilimaxNZ®有效地稳定了矢状面和额叶面的减压脊柱水平,同时允许很大一部分正向旋转,并且与之相比,它不会产生明显的ALE。融合。但是,它不能使减压后的样品扭转。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号