Graphical comparison of image analysis and laser diffraction particle size analysis data obtained from the measurements of nonspherical particle systems

机译:从非球形粒子系统的测量获得的图像分析和激光衍射粒度分析数据的图形比较

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The purpose of this paper is to describe results from the use of a set of Excel macros written to facilitate the comparison of image analysis (IA) and laser diffraction (LD) particle size analysis (psa) data. Measurements were made on particle systems of differing morphological characteristics including differing average aspect ratios, particle size distribution widths and modalities. The IA and LD psa data were plotted on the same graph treating both the weighting and the size unit of the LD psa data as unknowns. Congruency of the IA and LD plots was considered to indicate successful experimental determination of the weighting and size unit. The weighting of the resulting LD psa data (so-called volume-weighted) is shown to be better correlated with IA area-weighted data. The size unit of LD psa data is shown to be a function of particle shape. In the case of high aspect ratio particles characterized by approximately rectangular faces the LD psa data is shown to be a function of multiple particle dimensions being related to IA size descriptors through a simple variation of the law of mixtures. The results demonstrate that successful correlations between IA and LD psa data can be realized in the case of non-spherical particle systems even in the case of high aspect ratio particles; however, the inappropriateness of the application of the Equivalent Spherical Volume Diameter and the Random Particle Orientation assumptions to the interpretation of the LD psa results must first be acknowledged. Correlation permits cross validation of IA and LD psa results increasing confidence in the accuracy of the data from each orthogonal technique.
机译:本文的目的是描述一组Excel宏的使用结果,这些宏的编写旨在促进图像分析(IA)和激光衍射(LD)粒度分析(psa)数据的比较。对具有不同形态特征的颗粒系统进行了测量,包括不同的平均纵横比,粒径分布宽度和形态。 IA和LD psa数据绘制在同一张图上,将LD psa数据的权重和大小单位视为未知数。 IA和LD图的一致性被认为是实验成功地确定了权重和大小单位。结果表明,所得LD psa数据的权重(所谓的体积加权)与IA面积加权数据具有更好的相关性。 LD psa数据的大小单位显示为颗粒形状的函数。在以近似矩形的表面为特征的高长径比粒子的情况下,LD psa数据显示是通过简单改变混合物定律而与IA尺寸描述符相关的多个粒子尺寸的函数。结果表明,在非球形粒子系统中,即使在高纵横比粒子的情况下,也可以实现IA和LD psa数据之间的成功关联;但是,必须首先承认当量球体直径和随机粒子取向假设在解释LD psa结果时的不适当性。相关性允许对IA和LD psa进行交叉验证,从而提高了对每种正交技术的数据准确性的信心。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号