首页> 外文OA文献 >Quantitative thermal perception thresholds relative to exposure to vibration
【2h】

Quantitative thermal perception thresholds relative to exposure to vibration

机译:相对于振动的定量热感知阈值

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

OBJECTIVES—To assess the risk of disturbed thermal perception relative to exposure to vibration, to investigate a possible exposure-response relation and to analyse a possible relation between thermal perception and sensory symptoms.
METHODS—The study was based on a cross section of 123 male workers exposed to vibration and 62 male workers who were not exposed. Thermal perception of cold, warmth, and heat pain was bilaterally determined from the thenar eminence by the method of limits. Perception of cold and warmth were also tested in the second digit. Personal energy equivalent exposure to vibration was measured for all subjects. Vibration was measured in accordance with International Standards Organisation (ISO) 5349 and assessed separately for the left and right hand.
RESULTS—Combining exposure times and intensities gave the left hand an 0.80 exposure to vibration compared with the right. The risk of having contracted reduced thermal perception was increased at all test sites. The risk was higher for the thenar measurements than the finger measurements. A yearly extra contribution of 4000 mh/s2 in cumulative exposure increases the risk of contracting a wider neutral zone by 18% (95% confidence interval (95% CI) 1.06 to 1.32) for the right and 18% (1.05 to 1.32) for the left hand side. Subjects with symptoms of nocturnal paraesthesia had a rate ratio (95% CI) of 2.80 (1.17 to 6.67) for the right hand and 2.72 (1.12 to 6.63) for the left hand for increased neutral zones at the thenar eminence.
CONCLUSIONS—The results indicate thermal sensory impairment related to cumulative exposure to vibration. The effect appeared at vibration levels below the current guiding standard. Quantitative sensory testing of thermal perception offers the chance to assess this specific hazard to the peripheral sensorineural system associated with hand intensive work entailing vibration.


Keywords: quantitative thermal perception; heat pain; vibration; temperature threshold
机译:目的—评估相对于振动暴露的热感知受干扰的风险,研究可能的暴露-反应关系,并分析热感知与感觉症状之间的可能关系。方法-该研究基于123位暴露于振动的男性工人和62位未暴露于振动的男性工人的横截面。寒冷,温暖和热痛的热感是通过极限方法从双侧突出处双向确定的。第二个数字还测试了对寒冷和温暖的感知。对所有受试者测量相当于振动的个人能量暴露量。根据国际标准组织(ISO)5349测量振动,并分别评估左手和右手的振动。结果-结合曝光时间和强度,左手与右手相比有0.80的振动暴露。在所有测试部位,都有降低的热感知收缩的风险。相对于手指测量,测量纳那尔的风险更高。每年额外的4000 mh / s2的累积暴露量会增加右侧地区收缩18%(95%置信区间(95%CI)1.06至1.32)和18%(1.05至1.32)的风险。左手边夜间感觉异常症状的受试者右手的比率(95%CI)为2.80(1.17至6.67),左手的比率为2.72(1.12至6.63),以增加鼻翼突出处的中性区。结论—结果表明与累积的振动暴露有关的热感觉障碍。这种影响出现在低于当前指导标准的振动水平上。对热感知的定量感官测试提供了机会来评估与手部密集工作相关的对周围神经系统的特定危害,这会导致振动。关键词:定量热感知热痛振动;温度阈值

著录项

  • 作者

    Nilsson, T; Lundstrom, R;

  • 作者单位
  • 年度 2001
  • 总页数
  • 原文格式 PDF
  • 正文语种 en
  • 中图分类
  • 入库时间 2022-08-20 20:38:40

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号