Intensity-modulated radiotherapy (IMRT) clinical dose delivery is based on computer-controlled multileaf movements at different velocities. To test the accuracy of modulation of the beam periodically, quality assurance (QA) methods are necessary. Using a cylindrical phantom, dose delivery was checked at a constant geometry for sweeping fields. Repeated measurements with an in-house designed methodology over a period of 1 year indicate that the method is very sensitive to check the proper functioning of such dose delivery in medical linacs. A cylindrical perspex phantom with facility to accurately position a 0.6-cc (FC 65) ion chamber at constant depth at isocenter, (SA 24 constancy check tool phantom for MU check, Scanditronix Wellhofer) was used. Dosimeter readings were integrated for 4-mm, 10-mm, 20-mm sweeping fields and for 3 angular positions of the gantry periodically. Consistency of standard sweeping field output (10-mm slit width) and the ratios of outputs against other slit widths over a long period were reported. A 10-mm sweeping field output was found reproducible within an accuracy of 0.03% (n = 25) over 1 year. Four-millimeter, 20-mm outputs expressed as ratio with respect to 10-mm sweep output remained within a mean deviation of 0.2% and 0.03% respectively. Outputs at 3 gantry angles remained within 0.5%, showing that the effect of dynamic movements of multileaf collimator (MLC) on the output is minimal for angular positions of gantry. This method of QA is very simple and is recommended in addition to individual patient QA measurements, which reflect the accuracy of dose planning system. In addition to standard output and energy checks of linacs, the above measurements can be complemented so as to check proper functioning of multileaf collimator for dynamic field dose delivery.
机译:调强放疗(IMRT)临床剂量的输送是基于计算机控制的不同速度下的多叶运动。为了定期测试光束调制的准确性,必须使用质量保证(QA)方法。使用圆柱体模,以恒定的几何形状检查剂量传递范围。用内部设计的方法在1年内重复测量表明,该方法对检查这种剂量的直线加速器在医疗直线加速器中的正常运行非常敏感。使用了一个圆柱形的有机玻璃体模,该模体能够精确地将0.6 cc(FC 65)离子室精确定位在等中心点的恒定深度处(用于MU检查的SA 24恒定性检查工具体模,Scanditronix Wellhofer)。剂量计读数针对4毫米,10毫米,20毫米扫掠场和龙门架的3个角位置进行了定期积分。报告了长时间内标准扫场输出(缝隙宽度为10毫米)的一致性以及输出与其他缝隙宽度的比率。发现10毫米的扫视场输出在1年内可重现0.03%(n = 25)的精度。以相对于10毫米扫描输出的比率表示的4毫米20毫米输出分别保持在0.2%和0.03%的平均偏差内。 3个机架角度的输出保持在0.5%以内,表明对于机架的角位置,多叶准直器(MLC)的动态运动对输出的影响最小。这种质量保证方法非常简单,除了可以反映剂量计划系统准确性的个别患者质量保证测量值之外,建议使用该方法。除了直线加速器的标准输出和能量检查以外,上述测量结果可以得到补充,以便检查多叶准直仪对动态场剂量输送的正常功能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号