Influenza causes high morbidity and mortality in very young and elderly individuals, which can be controlled with antivirals and/or vaccines. The success of therapeutic measures is predicated on the rapid and precise diagnosis of the infection. We compared three rapid influenza immunoassay (RIIA) kits for the diagnosis of influenza virus A and B using 178 respiratory specimens submitted for routine testing. BD Directigen Flu A+B (Directigen), Directigen EZ Flu A+B (EZ), and NOW Flu A NOW Flu B (NOW; Binax) tests had comparable combined influenza virus A and B specificities, varying from 94 to 98%. In contrast, the sensitivity of EZ was significantly lower (39%) than that of NOW (76%) and marginally lower than that of Directigen (56%). The differences in sensitivity were most evident in patients who were >9 years old (Directigen, 53%; EZ, 32%; and NOW, 69%). Among specimens, bronchoalveolar lavage fluids yielded the most discrepant results, with sensitivities varying from 0 (EZ) to 100% (NOW), followed by nasopharyngeal swabs (sensitivities of 27 to 100%) and nasal washes (50 to 81%). The Directigen kit format allowed for faster completion but more cumbersome performance and more difficult interpretation compared with the other two kits. Overall, NOW provided the most accurate diagnoses and had user-friendly technical characteristics. However, the low overall sensitivity of the RIIAs indicates that these can be used as screening tools only.
机译:流行性感冒在非常年轻和年长的个人中引起很高的发病率和死亡率,可以通过抗病毒药和/或疫苗加以控制。治疗措施的成功取决于对感染的快速准确诊断。我们比较了使用178例呼吸道标本进行常规检测的三种快速流感免疫测定(RIIA)试剂盒对A和B型流感病毒的诊断。 BD Directigen流感A + B(Directigen),Directigen EZ流感A + B(EZ)和NOW流感A NOW流感B(NOW; Binax)检测具有可比的组合甲型和乙型流感病毒特异性,从94%到98%不等。相反,EZ的灵敏度显着低于NOW(76%)(39%),略低于Directigen(56%)。敏感性差异在> 9岁的患者中最为明显(Directigen,53%; EZ,32%; NOW,69%)。在标本中,支气管肺泡灌洗液的结果差异最大,敏感度从0(EZ)到100%(NOW)不等,其次是鼻咽拭子(敏感度为27至100%)和鼻腔清洗(50至81%)。与其他两个套件相比,Directigen套件格式可加快完成速度,但性能较笨拙,并且难以解释。总体而言,NOW提供了最准确的诊断,并具有用户友好的技术特征。但是,RIIA的总体敏感性较低,表明它们只能用作筛选工具。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号