We describe gravimetric methods for measuring the mass of droplets generated by a drop-on-demand (DOD) microdispenser. Droplets are deposited, either continuously at a known frequency or as a burst of known number, into a cylinder positioned on a submicrogram balance. Mass measurements are acquired precisely by computer, and results are corrected for evaporation. Capabilities are demonstrated using isobutyl alcohol droplets. For ejection rates greater than 100 Hz, the repeatability of droplet mass measurements was 0.2%, while the combined relative standard uncertainty (uc) was 0.9%. When bursts of droplets were dispensed, the limit of quantitation was 72 μg (1490 droplets) with uc = 1.0%. Individual droplet size in a burst was evaluated by high-speed videography. Diameters were consistent from the tenth droplet onward, and the mass of an individual droplet was best estimated by the average droplet mass with a combined uncertainty of about 1%. Diameters of the first several droplets were anomalous, but their contribution was accounted for when dispensing bursts. Above the limits of quantitation, the gravimetric methods provided statistically equivalent results and permit detailed study of operational factors that influence droplet mass during dispensing, including the development of reliable microassays and standard materials using DOD technologies.
机译:我们描述了用于测量按需滴落(DOD)微型分配器产生的液滴质量的重量分析方法。液滴以已知的频率连续或以已知数量的爆发形式沉积到位于亚微克秤上的圆柱体中。通过计算机精确地获取质量测量值,并针对蒸发校正结果。使用异丁醇液滴证明了能力。对于大于100 Hz的喷射速率,液滴质量测量的可重复性为0.2%,而组合的相对标准不确定度(uc)为0.9%。分配小滴液滴时,定量极限为72μg(1490个小滴),uc = 1.0%。通过高速摄影来评估突发中的单个液滴尺寸。从第十个液滴开始,直径保持一致,单个液滴的质量最好由平均液滴质量估算,合并不确定度约为1%。前几个液滴的直径是异常的,但在分配爆裂时会考虑它们的作用。超过定量极限,重量分析法提供了统计上等效的结果,并允许对影响点胶过程中液滴质量的操作因素进行详细研究,包括使用DOD技术开发可靠的微量分析和标准材料。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号