首页> 外文OA文献 >Comparison of Performance Characteristics of Three Real-Time Reverse Transcription-PCR Test Systems for Detection and Quantification of Hepatitis C Virus▿
【2h】

Comparison of Performance Characteristics of Three Real-Time Reverse Transcription-PCR Test Systems for Detection and Quantification of Hepatitis C Virus▿

机译:三种实时定量检测丙型肝炎病毒的实时逆转录-PCR测试系统的性能特点比较▿

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

We evaluated the performance characteristics of three real-time reverse transcription-PCR test systems for detection and quantification of hepatitis C virus (HCV) and performed a direct comparison of the systems on the same clinical specimens. Commercial HCV panels (genotype 1b) were used to evaluate linear range, sensitivity, and precision. The Roche COBAS TaqMan HCV test for research use only (RUO) with samples processed on the MagNA Pure LC instrument (Roche RUO-MPLC) and Abbott analyte-specific reagents (ASR) with QIAGEN sample processing (Abbott ASR-Q) showed a sensitivity of 1.0 log10 IU/ml with a linear dynamic range of 1.0 to 7.0 log10 IU/ml. The Roche ASR in combination with the High Pure system (Roche ASR-HP) showed a sensitivity of 1.4 log10 IU/ml with a linear dynamic range of 2.0 to 7.0 log10 IU/ml. All of the systems showed acceptable reproducibility, the Abbott ASR-Q being the most reproducible of the three systems. Seventy-six clinical specimens (50 with detectable levels of HCV RNA and various titers and genotypes) were tested, and results were compared to those of the COBAS Amplicor HCV Monitor v2.0. Good correlation was obtained for the Roche RUO-MPLC and Abbott ASR-Q (R2 = 0.84 and R2 = 0.93, respectively), with better agreement for the Abbott ASR-Q. However, correlation (R2 = 0.79) and agreement were poor for Roche ASR-HP, with bias relative to concentration and genotype. Roche ASR-HP underestimated HCV RNA for genotypes 3 and 4 as much as 2.19 log10 IU/ml. Our study demonstrates that Roche RUO-MPLC and Abbott ASR-Q provided acceptable results and agreed sufficiently with the COBAS Amplicor HCV Monitor v2.0.
机译:我们评估了三种实时逆转录PCR检测系统对丙型肝炎病毒(HCV)的检测和定量的性能特征,并在相同的临床标本上对该系统进行了直接比较。商业HCV面板(基因型1b)用于评估线性范围,灵敏度和精度。 Roche COBAS TaqMan HCV测试仅用于研究(RUO),在MagNA Pure LC仪器(Roche RUO-MPLC)上处理过的样品以及在QIAGEN样品处理(Abbott ASR-Q)下的雅培分析物专用试剂(ASR)显示出灵敏度浓度为1.0 log10 IU / ml,线性动态范围为1.0至7.0 log10 IU / ml。罗氏ASR与高纯度系统(Roche ASR-HP)结合使用时,灵敏度为1.4 log10 IU / ml,线性动态范围为2.0至7.0 log10 IU / ml。所有系统均显示出可接受的重现性,雅培ASR-Q在这三个系统中重现性最高。测试了76份临床标本(其中50份具有可检测的HCV RNA水平以及各种效价和基因型),并将结果与​​COBAS Amplicor HCV Monitor v2.0的结果进行了比较。罗氏RUO-MPLC和雅培ASR-Q的相关性良好(分别为R2 = 0.84和R2 = 0.93),而雅培ASR-Q的一致性更好。然而,罗氏ASR-HP的相关性(R2 = 0.79)和一致性较差,相对于浓度和基因型存在偏倚。罗氏ASR-HP低估了基因型3和4的HCV RNA,最高为2.19 log10 IU / ml。我们的研究表明,罗氏RUO-MPLC和雅培ASR-Q提供了可接受的结果,并与COBAS Amplicor HCV Monitor v2.0充分吻合。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号