Micropuncture studies were performed in the rabbit to determine nephron filtration rate and absolute fluid reabsorption in the proximal tubule in order to compare the latter value with data obtained with the in vitro microperfusion technique. New Zealand white rabbits, 2-2.8 kg, were studied. Nephron filtration rate was 21 nl/min (n equal to 48) and absolute reabsorption along the length of the accesible portion of the proximal convoluted tubule was 10.3 nl/min. Correcting this value for tubular length gives a fluid reabsorption of approximately 1.9 nl/mm per min. In view of the marked difference between the in vivo and in vitro techniques and the various sources of error with each, this is reasonably similiar to the value of 1.3 nl/mm per min obtained in the isolated proximal convoluted tubule.
机译:在兔中进行微穿刺研究以确定肾单位的滤过率和近端小管中的绝对液体重吸收,以便将后者的值与体外微灌注技术获得的数据进行比较。研究了2-2.8千克的新西兰白兔。 Nephron过滤速率为21 nl / min(n等于48),沿近端旋回小管可触及部分的长度的绝对重吸收为10.3 nl / min。校正此值以得到管状长度,可以使流体每分钟重新吸收约1.9 nl / mm。考虑到体内和体外技术之间的显着差异以及每种技术的不同误差来源,这在合理意义上类似于在分离的近端曲折小管中获得的每分钟1.3 nl / mm的值。