首页> 外文OA文献 >NHANES Monitoring of Serum 25-Hydroxyvitamin D: A Roundtable Summary123
【2h】

NHANES Monitoring of Serum 25-Hydroxyvitamin D: A Roundtable Summary123

机译:NHANES监测血清25-维生素D的圆桌会议总结123

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

A roundtable to discuss monitoring of serum 25-hydroxyvitamin D [25(OH)D] in the NHANES was held in late July 2009. Topics included the following: 1) options for dealing with assay fluctuations in serum 25(OH)D in the NHANES conducted between 1988 and 2006; 2) approaches for transitioning between the RIA used in the NHANES between 1988 and 2006 to the liquid chromatography tandem MS (LC-MS/MS) measurement procedure to be used in NHANES 2007 and later; 3) approaches for integrating the recently available standard reference material for vitamin D in human serum (SRM 972) from the National Institute of Standards and Technology (NIST) into the NHANES; 4) questions regarding whether the C-3 epimer of 25-hydroxyvitamin D3 [3-epi-25(OH)D3] should be measured in NHANES 2007 and later; and 5) identification of research and educational needs. The roundtable experts agreed that the NHANES data needed to be adjusted to control for assay fluctuations and offered several options for addressing this issue. The experts suggested that the LC-MS/MS measurement procedure developed by NIST could serve as a higher order reference measurement procedure. They noted the need for a commutability study for the recently released NIST SRM 972 across a range of measurement procedures. They suggested that federal agencies and professional organizations work with manufacturers to improve the quality and comparability of measurement procedures across all laboratories. The experts noted the preliminary nature of the evidence of the 3-epi-25(OH)D3 but felt that it should be measured in 2007 NHANES and later.
机译:2009年7月下旬举行了一次圆桌会议,讨论在NHANES中监测血清25-羟基维生素D [25(OH)D]的问题。主题包括以下内容:1)处理血清中25(OH)D含量波动的方法。 1988年至2006年进行的NHANES; 2)在1988年至2006年NHANES中使用的RIA过渡到NHANES 2007年及以后使用的液相色谱串联MS(LC-MS / MS)测量程序的方法; 3)将美国国家标准技术研究所(NIST)最近提供的人体血清中维生素D标准参考物质(SRM 972)整合到NHANES中的方法; 4)是否应在NHANES 2007及更高版本中测量25-羟基维生素D3 [3-epi-25(OH)D3]的C-3差向异构体的问题; 5)确定研究和教育需求。圆桌会议专家一致认为,需要调整NHANES数据以控制化验波动,并提供了解决此问题的几种选择。专家建议,由NIST开发的LC-MS / MS测量程序可以作为高阶参考测量程序。他们指出,对于最近发布的NIST SRM 972,需要在一系列测量过程中进行可换性研究。他们建议联邦机构和专业组织与制造商合作,以改善所有实验室中测量程序的质量和可比性。专家们指出了3-epi-25(OH)D3证据的初步性质,但认为应该在2007年NHANES及以后的时间进行测量。

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号