首页> 外文OA文献 >Comparison of a Multiplex Flow Cytometric Assay with Enzyme-Linked Immunosorbent Assay for Quantitation of Antibodies to Tetanus, Diphtheria, and Haemophilus influenzae Type b
【2h】

Comparison of a Multiplex Flow Cytometric Assay with Enzyme-Linked Immunosorbent Assay for Quantitation of Antibodies to Tetanus, Diphtheria, and Haemophilus influenzae Type b

机译:多重流式细胞术测定与酶联免疫吸附法定量检测破伤风,白喉和流感嗜血杆菌b型抗体的比较

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

We developed a multiplexed indirect immunofluorescence assay for antibodies to Haemophilus influenza type b (Hib) polysaccharide and the toxoids of Clostridium tetani (Tet) and Corynebacterium diphtheriae (Dip) based on the Luminex multiple-analyte profiling system. A pooled serum standard was calibrated against World Health Organization standards for Dip and Tet and an international standard for Hib. The multiplexed Luminex assay was compared to individual enzyme-linked immunosorbent assays (ELISAs) for the same analytes. By both methods, 75 (92.6%) of 81 of random serum samples had protective levels of antibody to Tet (≥0.1 IU/ml). For Dip, 81.5% of the samples had protective antibody levels (≥0.1 IU/ml) by ELISA and 80.2% had protective antibody levels by Luminex. Protective levels (≥1.0 μg/ml) of antibody to Hib were found in 45.0% of the samples tested by ELISA and in 39.0% of the samples tested by Luminex. The correlations (R2) between ELISA and Luminex of the 81 samples were 0.96, 0.96, and 0.91 for Tet, Dip, and Hib, respectively. There was also similar agreement between Luminex and ELISA for sera collected before and 1 month after Tet, Dip, and Hib vaccine administration. Both methods detected strong postvaccination responses. The Luminex method is an attractive alternative to ELISA since it reduces labor and reagent costs, as well as assay time.
机译:我们开发了基于Luminex多种分析物谱分析系统的针对乙型流感嗜血杆菌(Hib)多糖和破伤风梭状芽胞杆菌(Tet)和白喉棒状杆菌(Dip)类毒素的抗体的间接免疫荧光多重检测方法。参照世界卫生组织关于Dip和Tet的标准和针对Hib的国际标准对合并的血清标准进行校准。将Luminex多重检测与相同分析物的单独酶联免疫吸附测定(ELISA)进行比较。通过这两种方法,在81个随机血清样本中,有75个(92.6%)具有针对Tet的抗体保护水平(≥0.1IU / ml)。对于Dip,通过ELISA的样本中有81.5%具有保护性抗体水平(≥0.1 IU / ml),而通过Luminex有80.2%的样本具有保护性抗体水平。通过ELISA测试的样品中有45.0%和通过Luminex测试的样品中有39.0%发现了针对Hib的保护水平(≥1.0μg/ ml)。 ELISA和Luminex在81个样品中的Tet,Dip和Hib相关性(R2)分别为0.96、0.96和0.91。 Luminex和ELISA在Tet,Dip和Hib疫苗接种之前和之后1个月收集的血清之间也达成了类似的协议。两种方法均检测到强烈的疫苗接种后反应。 Luminex方法是ELISA的一种有吸引力的替代方法,因为它减少了人工和试剂成本以及测定时间。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号