Selective Spectrophotometric and Spectrofluorometric Methods for the Determination of Amantadine Hydrochloride in Capsules and Plasma via Derivatization with 1,2-Naphthoquinone-4-sulphonate

机译:1,2-萘醌-4-磺酸酯衍生化的选择性分光光度法和荧光分光光度法测定胶囊和血浆中的盐酸金刚烷胺

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

New selective and sensitive spectrophotometric and spectrofluorometric methods have been developed and validated for the determination of amantadine hydrochloride (AMD) in capsules and plasma. The methods were based on the condensation of AMD with 1,2-naphthoquinone-4-sulphonate (NQS) in an alkaline medium to form an orange-colored product. The spectrophotometric method involved the measurement of the colored product at 460  nm. The spectrofluorometric method involved the reduction of the product with potassium borohydride, and the subsequent measurement of the formed fluorescent reduced AMD-NQS product at 382  nm after excitation at 293  nm. The variables that affected the reaction were carefully studied and optimized. Under the optimum conditions, linear relationships with good correlation coefficients (0.9972–0.9974) and low LOD (1.39 and 0.013 μg mL−1) were obtained in the ranges of 5–80 and 0.05–10  μg mL−1 for the spectrophotometric and spectrofluorometric methods, respectively. The precisions of the methods were satisfactory; RSD ≤2.04%. Both methods were successfully applied to the determination of AMD in capsules. As its higher sensitivity, the spectrofluorometric method was applied to the determination of AMD in plasma; the recovery was 96.3–101.2 ± 0.57–4.2%. The results obtained by the proposed methods were comparable with those obtained by the official method
机译:已开发出新的选择性和灵敏分光光度法和荧光光谱法,用于测定胶囊和血浆中的盐酸金刚烷胺(AMD)。该方法基于AMD与1,2-萘醌-4-磺酸盐(NQS)在碱性介质中的缩合形成橙色产物。分光光度法涉及在460 nm下测量有色产品。荧光光谱法包括用硼氢化钾还原产物,然后在293nm激发后,在382nm处测定形成的荧光还原AMD-NQS产物。仔细研究和优化了影响反应的变量。在最佳条件下,分光光度法和荧光分光光度法在5–80和0.05–10 μg−mL-1范围内获得了具有良好相关系数(0.9972–0.9974)和较低LOD(1.39和0.013μgmL-1)的线性关系。方法。该方法的精密度令人满意。 RSD≤2.04%。两种方法均成功应用于胶囊中AMD的测定。荧光分光光度法具有较高的灵敏度,可用于血浆中AMD的测定。回收率为96.3–101.2±0.57–4.2%。通过提议的方法获得的结果与通过官方方法获得的结果相当

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号