首页> 外文OA文献 >Occupational exposure to polychlorinated biphenyls in electrical workers. I. Environmental and blood polychlorinated biphenyls concentrations.
【2h】

Occupational exposure to polychlorinated biphenyls in electrical workers. I. Environmental and blood polychlorinated biphenyls concentrations.

机译:电业工人的职业接触多氯联苯。 I.环境和血液中多氯联苯的浓度。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Industrial exposure to polychlorinated biphenyls (PCBs) and internal dose were investigated in 80 worker exposed for many years to PCB mixtures with a 42% chlorine content (Pyralene 3010 and Apirolio). PCBs were determined by liquid gas chromatography on samples taken from workroom air, workroom surfaces and tools, the palms of the hand, and the blood of the workers. In the workroom air samples, PCB concentrations ranged from 48 to 275 micrograms/m3. All tested surfaces and tools were heavily contaminated, with a range from 0.2 to 159 micrograms PCBs per cm2 of surface. Considerable amounts of PCBs were detected on the palms of the hands of the workers (2-28 microgram/cm2 of skin surface). In blood, total PCB concentrations from 88 to 1319 micrograms/kg were observed: comparing the blood concentrations of low and high chlorine content biphenyls, a significant difference was found for the low-chlorinated biphenyl concentrations between workers currently exposed and workers exposed only in the past. In groups of workers who were homogeneous as regards work area and job, the PCB concentrations in the blood were closely correlated with the length of actual occupational exposure to these compounds. These findings led to the conclusion that absorption of PCBs in these workers had occurred mainly through the skin, therefore industrial preventive surveillance must take this route of exposure into account. Since blood PCB concentrations appear to be correlated with the length of exposure, PCB determination on whole blood may be used to monitor industrial and environmental exposure to PCBs.
机译:对80名工人进行了多年工业暴露于多氯联苯(PCBs)和内部剂量的调查,这些工人多年接触了含42%氯的PCB混合物(Pyralene 3010和Apirolio)。多氯联苯是通过液相气相色谱法测定的,这些样品取自工作场所的空气,工作场所的表面和工具,手掌和工人的血液。在工作室的空气样本中,PCB的浓度范围为48至275微克/立方米。所有测试的表面和工具都被严重污染,每平方厘米表面的PCB含量为0.2至159微克。在工人的手掌上检测到大量的多氯联苯(2-28微克/平方厘米的皮肤表面)。在血液中,PCB的总浓度为88到1319微克/ kg:比较低氯含量和高氯含量联苯的血液浓度,发现目前和仅接触过低氯联苯的工人之间的低氯联苯浓度存在显着差异。过去。在工作区域和工作方面均一的工人群体中,血液中的PCB浓度与这些化合物的实际职业暴露时间密切相关。这些发现得出的结论是,这些工人中多氯联苯的吸收主要是通过皮肤吸收的,因此工业预防性监测必须考虑到这种接触途径。由于血液中的PCB浓度似乎与暴露时间长短相关,因此可以通过对全血进行PCB测定来监测工业和环境中PCB的暴露。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号