BACKGROUND--The "Escort" spirometer is a lightweight, hand held spirometer employing a Fleisch pneumotachograph. Measurements of forced expiratory volume in one second (FEV1), forced vital capacity (FVC), and peak expiratory flow (PEF) are obtained from a single FVC manoeuvre. Results are displayed on a small liquid crystal display, but there is no graphical display. The performance of the Escort spirometer has been compared with that of a wedge bellows spirometer (Vitalograph S model) and a Wright PEF meter. METHODS--One hundred and thirteen subjects performed three FVC manoeuvres on the wedge bellows and Escort spirometers and three PEF manoeuvres on the Wright meter. The best reading for each index was recorded. In 21 of the subjects comparison of a Wright manoeuvre with an FVC manoeuvre on the Escort spirometer was performed, whilst in three subjects the effect of repeated blows was studied. RESULTS--The FEV1 ranged from 0.5 to 5.4 litres, FVC from 1.05 to 6.2 litres, and PEF from 100 to 725 l/min. The mean (SD) difference for the FEV1 was -0.05 (0.15) (95% confidence interval (95% CI) -0.07 to -0.02) litres, for FVC 0.03 (0.28) (95% CI -0.02 to +0.08) litres, and for PEF 1.68 (50.6) (95% CI -7.7 to +11.1) l/min. The differences were positively correlated with the mean reading for PEF and FVC but not for FEV1. The Wright PEF manoeuvre performed on the Escort produced significantly higher PEF readings (mean difference -22.9 litres). There was no significant effect of repeated FVC manoeuvres on any of the indices. CONCLUSIONS--The Escort spirometer compares extremely well with a wedge bellows spirometer for measurement of FEV1 and FVC, whilst yielding results of PEF from an FVC manoeuvre which are comparable to those obtained from a Wright meter. It can be recommended for use as a portable hand held spirometer.
机译:背景技术“ Escort”肺活量计是一种轻巧的手持式肺活量计,采用了Fleisch气动速度描记器。一秒钟的强制呼气量(FEV1),强制肺活量(FVC)和呼气峰值流量(PEF)的测量是从单个FVC动作获得的。结果显示在一个小的液晶显示器上,但是没有图形显示。已将Escort肺活量计的性能与楔形波纹管肺活量计(Vitalograph S型号)和Wright PEF仪表的性能进行了比较。方法-113位受试者在楔形风箱和Escort肺活量计上进行了3次FVC操作,在Wright仪表上进行了3次PEF操作。记录每个索引的最佳读数。在21名受试者中,对Escort肺活量计上的Wright操纵与FVC操纵进行了比较,而在三名受试者中,研究了反复打击的效果。结果-FEV1为0.5至5.4升,FVC为1.05至6.2升,PEF为100至725 l / min。 FVC1的平均(SD)差异为-0.05(0.15)(95%置信区间(95%CI)-0.07至-0.02)升,而FVC为0.03(0.28)(95%CI -0.02至+0.08)升,而对于PEF 1.68(50.6)(95%CI -7.7至+11.1)l / min。差异与PEF和FVC的平均读数呈正相关,而与FEV1的则不相关。在护送上执行的莱特(Wright)PEF操作产生了更高的PEF读数(平均差-22.9升)。重复进行FVC操作对任何指数均无明显影响。结论-Escort肺活量计与楔形波纹管肺活量计在测量FEV1和FVC方面具有非常好的对比,同时从FVC操纵获得的PEF结果与从Wright仪表获得的结果相当。推荐将其用作便携式手持式肺活量计。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号