首页> 外文OA文献 >UK Naval Dockyards Asbestosis Study: radiological methods in the surveillance of workers exposed to asbestos
【2h】

UK Naval Dockyards Asbestosis Study: radiological methods in the surveillance of workers exposed to asbestos

机译:英国海军造船厂石棉病研究:放射方法监测石棉工人

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

ABSTRACT In a survey of the effects of exposure to asbestos in the UK Naval Dockyards, small- and large-film chest radiographs of 674 men have been examined. These films have been read under survey conditions by two readers using a simple screening classification, and also in a controlled trial by five readers using the full ILO U/C classification. Comparison between the reading methods showed a deficiency, independent of the size of film, of at least 30% in the detection of asbestos-related radiographic abnormalities when the screening classification was used. For adequate diagnostic sensitivity the ILO U/C classification appears to be essential. There was a deficiency of 43% in significant abnormalities observed by a majority of readers in the small films when directly compared with large film readings. This deficiency could be reduced to 7% by using readings of the small films at any level of abnormality by any of the five readers. When the ILO U/C readings were related to the clinical diagnoses, the only abnormality missed was a small pleural plaque. Films with previously agreed coding were inserted at intervals during the reading trial and helped to maintain the consistency of reading. Right oblique views were taken for 1884 men, in addition to the full-sized postero-anterior view, but the contribution provided by this view proved insufficient to justify its use in large surveys. The cost of a survey when small films are used as a screening method is reduced to between one-third and one-half of the cost when large films are used, assuming that the abnormality rate is not more than 5%. However, this cost advantage for small films is likely to be overtaken by the development of automatic large-film units. The radiation dose when small films are used is increased by a factor of about 20, but is within the prescribed safety level. It is concluded that at least three readers should be involved, using the full ILO U/C classification. Small films may be of particular use in a large-scale survey, in which the abnormality rate is expected to be low, and which might otherwise be too expensive. A sensitive reading method and a high standard of film quality are essential factors in the use of this technique.
机译:摘要在对英国海军造船厂接触石棉的影响进行的一项调查中,对674名男性的小片和大片胸部X光片进行了检查。这些影片在调查条件下由两名读者使用简单的筛选分类进行了阅读,并且在对照试验中,由五名读者使用完整的ILO U / C分类进行了对照试验。两种阅读方法之间的比较显示,当使用筛查分类时,在检测与石棉有关的射线照相异常方面,与胶片大小无关,至少有30%的缺陷。为了获得足够的诊断敏感性,ILO U / C分类似乎至关重要。与大型电影的读数直接比较时,大多数读者在小型电影中观察到的重大异常不足43%。通过使用五个阅读器中任何异常水平的小电影读数,可以将这种缺陷减少到7%。当ILO U / C读数与临床诊断相关时,唯一遗漏的异常是小胸膜斑块。阅读试验期间,间隔一定时间插入具有先前约定编码的影片,这有助于保持阅读的一致性。除了全尺寸的后前视图外,还为1884名男性拍摄了右斜视图,但该视图提供的贡献不足以证明其可用于大规模调查。假设异常率不超过5%,使用小胶片作为筛选方法的调查成本可降低到使用大胶片时的三分之一至一半。但是,小胶片的这种成本优势很可能会被自动大胶片装置的开发所超越。使用小薄膜时的辐射剂量增加了约20倍,但在规定的安全级别之内。结论是,使用完整的ILO U / C分类,至少应涉及三名读者。小胶片可能在大规模调查中特别有用,在这种调查中,异常率预计会很低,否则可能会太昂贵。灵敏的读取方法和高品质的胶片质量是使用该技术的必要因素。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号