Normal ulnar nerve conduction velocity across the thoracic outlet: comparison of two measuring techniques.

机译:横跨胸廓出口的正常尺神经传导速度:两种测量技术的比较。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Comparison of ulnar nerve conduction across the thoracic outlet in 30 normal individuals using caliper and steel tape measurements is reported. A difference of 11.3 m/s was noted between the two methods (58.9 +/- 4.20 m/s by caliper; 70.2 +/- 5.20 m/s by tape). Comparison of these values with previous studies and the use of the opposite limb as a control are discussed. This procedure is of clinical importance in the diagnosis of nerve compression in the thoracic outlet syndrome.
机译:据报道,使用卡尺和钢带测量法比较了30名正常人跨胸腔出口的尺神经传导。两种方法之间的差异为11.3 m / s(卡尺为58.9 +/- 4.20 m / s;卷尺为70.2 +/- 5.20 m / s)。讨论了将这些值与以前的研究进行比较,以及使用对侧肢作为对照。该过程对诊断胸廓出口综合征的神经受压具有重要的临床意义。