首页> 外文OA文献 >Histamine dose-response curves in asthma: reproducibility and sensitivity of different indices to assess response.
【2h】

Histamine dose-response curves in asthma: reproducibility and sensitivity of different indices to assess response.

机译:哮喘中组胺的剂量反应曲线:重现性和敏感性的不同指标,以评估反应。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

In 18 clinically stable asthmatic patients histamine inhalation challenges were performed with a Wright's nebuliser and tidal volume breathing for two minutes on two to four occasions for each subject at a maximum interval of two weeks. The response was measured in terms of specific lung conductance (sGL) by the subtraction technique, maximum partial and maximum complete expiratory flow at 40% and 50% of vital capacity respectively (Vmax40p and Vmax50c), and FEV1 from the maximum flow-volume curve. Dose-response curves were analysed for (1) provocative concentration (PC) of histamine causing a 20% fall in FEV1 and a 40% change in the other measurements; (2) threshold concentration (TC)--the concentration at which changes in the measurement exceed 2 SD from control values; (3) reactivity (R)--the slope of the dose-response curve beyond TC. We found that PC20-FEV1 was the most reproducible index, the 95% confidence intervals based on a single determination being +/- 1.6 single two-fold concentration difference. PC20-FEV1 was more reproducible than PC values for other measurements and more reproducible than any of the TC values. The 95% confidence intervals based on a single determination of R varied from +/- 52% to +/- 74% change/log histamine concentration. Both sGL and Vmax40p detected the bronchoconstrictor response assessed by PC and TC at a significantly lower histamine concentration than FEV1 (p less than 0.01 and p less than 0.05 respectively). PC and TC results showed a significant correlation, but neither were correlated with R.
机译:在18名临床稳定的哮喘患者中,对每位受试者进行2次至4次Wright雾化器和潮气量呼吸2分钟,以最大间隔为两周的时间进行组胺吸入攻击。通过减法技术,比肺电导率(sGL),分别在最大通气量(Vmax40p和Vmax50c)的40%和50%的最大通气量(Vmax40p和Vmax50c)以及最大通气量曲线上的FEV1来测量反应。分析了剂量-响应曲线,分析了(1)组胺的激发浓度(PC),导致FEV1下降20%,其他测量值变化40%; (2)阈值浓度(TC)-测量值的变化超过对照值的2 SD; (3)反应性(R)-超过TC的剂量反应曲线的斜率。我们发现PC20-FEV1是最可重复的指数,基于单次测定的95%置信区间为+/- 1.6单一的两倍浓度差。在其他测量中,PC20-FEV1的重现性比PC值高,并且比任何TC值重现性更高。基于对R的单次测定,95%的置信区间在+/- 52%到+/- 74%变化/对数组胺浓度之间变化。 sGL和Vmax40p均检测到PC和TC评估的支气管收缩反应的组胺浓度明显低于FEV1(p分别小于0.01和p小于0.05)。 PC和TC结果显示出显着的相关性,但均与R无关。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号