The improvement of a low concentration gas detection system based on the intracavity fiber laser is proposed in this paper. The sensitivity of the system is deduced based on Lambert–Beer law. The optimized system was established with the gas cell made elaborately. In order to apply the wavelength sweeping technique, the fiber Bragg grating reflector was substituted by the wavelength independent Faraday rotation reflector. The sensitivity of the system for acetylene detection is reduced to less than 100 ppm by using the average of three absorption spectra. The acetylene detection coefficients of variation with different concentrations are measured. The gas measurement system is validated to detect low concentration gas effectively.
机译:提出了一种基于腔内光纤激光器的低浓度气体检测系统的改进方案。系统的灵敏度是根据兰伯特-比尔定律推论得出的。建立了优化的系统,并精心制作了气室。为了应用波长扫描技术,将光纤布拉格光栅反射器替换为与波长无关的法拉第旋转反射器。通过使用三个吸收光谱的平均值,用于乙炔检测的系统的灵敏度降低到小于100 ppm。测量不同浓度的乙炔检测系数的变化。气体测量系统经过验证可有效检测低浓度气体。