首页> 外文OA文献 >Dose rate measurements in the cobalt-60 gamma irradiation facility using thermoluminescent dosimeters
【2h】

Dose rate measurements in the cobalt-60 gamma irradiation facility using thermoluminescent dosimeters

机译:使用热致发光剂量计在钴60γ辐照设备中进行剂量率测量

摘要

A dose rate measurement survey was performed at various locations inside the radiation chamber of the Cobalt-60 gamma irradiation facility located in Room 130, Building 20 at the University of Arizona. TLDs were used for the dose rate measurements. It was observed that the dose rates decrease rapidly with increasing distance from the source. Also, dose rates decreased with increased distance away from the centerline of the radiation chamber which is indicative of the position of the effective center of the source. Percent dose rates with respect to the dose rate of the calibration position were tabulated.
机译:在位于亚利桑那大学20号楼130室的Cobalt-60伽马辐照设施的辐射室内的各个位置进行了剂量率测量调查。 TLD用于剂量率测量。观察到剂量率随着距放射源距离的增加而迅速降低。而且,剂量率随着远离辐射室中心线的距离的增加而降低,这表明源的有效中心的位置。将相对于校准位置的剂量率的剂量率列表。

著录项

  • 作者

    Quinn Bruce David 1955-;

  • 作者单位
  • 年度 1991
  • 总页数
  • 原文格式 PDF
  • 正文语种 en_US
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号