首页> 外文OA文献 >Dose rate measurements in the cobalt-60 gamma irradiation facility using thermoluminescent dosimeters
【2h】

Dose rate measurements in the cobalt-60 gamma irradiation facility using thermoluminescent dosimeters

机译:使用热致发光剂量计在钴60γ辐照设备中进行剂量率测量

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

A dose rate measurement survey was performed at various locations inside the radiation chamber of the Cobalt-60 gamma irradiation facility located in Room 130, Building 20 at the University of Arizona. TLDs were used for the dose rate measurements. It was observed that the dose rates decrease rapidly with increasing distance from the source. Also, dose rates decreased with increased distance away from the centerline of the radiation chamber which is indicative of the position of the effective center of the source. Percent dose rates with respect to the dose rate of the calibration position were tabulated.
机译:在位于亚利桑那大学20号楼130室的Cobalt-60伽马辐照设施的辐射室内的各个位置进行了剂量率测量调查。 TLD用于剂量率测量。观察到剂量率随着距放射源距离的增加而迅速降低。而且,剂量率随着远离辐射室中心线的距离的增加而降低,这表明源的有效中心的位置。将相对于校准位置的剂量率的剂量率列表。