摘要

The refrigerant blend R-507A (50 wt % HFC-143a, 50 wt % HFC-125) is an azeotropic mixture of hydrofluorocarbon refrigerants, 1,1,1-trifluoroethane (HFC-143a) and pentafluoroethane (HFC-125). The paperreports viscosity measurements, performed with a vibrating-wire viscometer, of the refrigerant blend R-507A,at five temperatures in the range (253 to 293) K. The measurements were carried out at pressures from slightly above saturation up to 10 MPa, except for the isotherms at 253.26 K where the maximum pressure was 7.52 MPa and at 263.23 K where the maximum pressure was 7.09 MPa. The overall uncertainty of these measurements is estimated to be ( 1.0 %. The data obtained were correlated by means of a modifiedhard-sphere based correlation technique. The root-mean-square deviation, rmsd, of the experimental results from the correlation equations is 0.23 %, and their bias is not significant. This correlation method has alsobeen used to interpolate and extrapolate the present results to enable comparisons with measurements performed by other authors of the viscosity of liquid R-507A at different temperatures and pressures.
机译:制冷剂混合物R-507A(50 wt%HFC-143a,50 wt%HFC-125)是氢氟烃制冷剂,1,1,1-三氟乙烷(HFC-143a)和五氟乙烷(HFC-125)的共沸混合物。本文使用振动线粘度计在253至293 K范围内的五个温度下用振动线粘度计对粘度进行了测量。该测量是在略高于饱和度且最高压力为10 MPa的压力下进行的,除了最大压力为7.52 MPa的253.26 K和最大压力为7.09 MPa的263.23 K时的等温线。这些测量的总体不确定度估计为(1.0%。所得数据通过改进的基于硬球的相关技术进行相关。相关方程的实验结果的均方根偏差rmsd为0.23此相关方法也已用于对当前结果进行内插和外推,以便与其他作者在不同温度和压力下对液体R-507A粘度的测量结果进行比较。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号