Near-surface seismic refraction and electrical resistivity methods were used to characterise the subsurfaceudcondition of a site reclaimed from water bodies in order to determine its competence for construction purposes. Nine seismicudrefraction profiles were acquired and the results were interpreted using SeisImager software. Also, twelve vertical electricaludsoundings were conducted and the acquired data were interpreted using WinResist computer package. Four-five geoelectricudlayers were delineated and the resistivity values obtained ranges between 23.3 and 1705.1m . The result of the resistivityudmethod showed that the third layer is the most competent layer in the study area. The depth of this layer is between 7.5 m andud51 m in the subsurface. In a related development, three layers were delineated by the seismic refraction method and the thirdudlayer which is between 7 m and 18 m, may be the most competent because it had the highest engineering parameters. TheudYoung modulus of the competent layer at this site ranges between 1.558 and 25.106 GPa and bulk modulus ranges fromud0.999 to 16.093GPa , it was also noted that the shear modulus ranges between 0.638 and 10.123 GPa . There is anudagreement in the results of the two methods of investigation. Therefore, it was recommended that some form of arrangementudmust be made to transfer the load from the civil engineering construction to the most competent layer underneath so as toudavoid building failure.
机译:为了确定其在施工中的能力,使用了近地表地震折射法和电阻率法来表征从水体中回收的场地的地下状况。采集了9个地震/非折射剖面,并使用SeisImager软件解释了结果。另外,进行了十二次垂直的电气探测,并使用WinResist计算机软件包对获取的数据进行了解释。划定了四层五层地电层,电阻率值在23.3至1705.1m之间。电阻率 udmethod的结果表明,第三层是研究区域中最有效的层。在地下,该层的深度在7.5 m至ud51 m之间。在相关的开发中,通过地震折射法描绘了三层,并且在7 m至18 m之间的第三层可能是最有效的,因为它具有最高的工程参数。该部位的感受层的杨氏模量在1.558至25.106GPa之间,体积模量在ud0.999至16.093GPa之间,还注意到剪切模量在0.638至10.123GPa之间。两种调查方法的结果存在分歧。因此,建议采取某种形式的布置,以将载荷从土木工程施工转移到最下层的主管层,以免建筑物倒塌。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号