首页> 外文OA文献 >Suspect screening of halogenated carboxylic acids in drinking water using ion exchange chromatography – high resolution (Orbitrap) mass spectrometry (IC-HRMS)
【2h】

Suspect screening of halogenated carboxylic acids in drinking water using ion exchange chromatography – high resolution (Orbitrap) mass spectrometry (IC-HRMS)

机译:使用离子交换色谱法–高分辨率(Orbitrap)质谱(IC-HRMS)来可疑筛查饮用水中的卤代羧酸

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Retrospective in silico screening of analytical data for the identification of new or emerging disinfection by-products in drinking waters could be useful to assess quality and potential hazards, as well as help implement mitigation procedures more rapidly. Herein, the first study coupling ion exchange chromatography (IC) with high resolution mass spectrometry (HRMS) for the determination of halogenated carboxylic acid disinfectant by-products is reported. Separation was achieved using a Metrohm A Supp 5 column and a Na2CO3/NaHCO3 gradient eluent from 1/0.31 to 10/3.1 mM. A variety of solid phase extraction (SPE) sorbents were tested for added selectivity to organic ions and Isolute ENV+ cartridges were selected because of their best overall extraction performance. Method LODs were in the μg L−1 concentration range, with R2 ≥ 0.99 for all the analytes, and isobaric ions could be easily discriminated using HRMS. The method was applied to municipal drinking water. Targeted quantitative analysis revealed the presence of 10 haloacetic acids at levels not exceeding the limits set by WHO and USEPA. Furthermore, suspect screening for additional halogenated carboxylic acids via retrospective HRMS data analysis also indicated the presence of other iodinated HAAs and chlorinated propionic acids, of which one (i.e. monochloropropionic acid) is discussed here for the first time. Most importantly, several potential suspects could be eliminated from further consideration through HRMS data analysis alone. To our knowledge, this represents the first time that a retrospective IC-HRMS screen of halogenated carboxylic acids in drinking water has been reported.
机译:对分析数据进行回顾性计算机模拟筛选,以识别饮用水中新出现的或正在出现的消毒副产物,可能有助于评估质量和潜在危害,并有助于更快地实施缓解程序。本文中,首次报道了将离子交换色谱(IC)与高分辨率质谱(HRMS)耦合用于测定卤代羧酸消毒剂副产物的研究。使用Metrohm A Supp 5色谱柱和Na2CO3 / NaHCO3梯度洗脱液从1 / 0.31到10 / 3.1 mM进行分离。测试了各种固相萃取(SPE)吸附剂对有机离子的选择性,并选择了Isolute ENV +柱,因为它们具有最佳的整体萃取性能。方法LOD的浓度在μgL-1范围内,所有分析物的R2≥0.99,并且使用HRMS可以轻松区分同量离子。该方法应用于市政饮用水。有针对性的定量分析表明,存在的10种卤代乙酸的含量不超过WHO和USEPA设定的限值。此外,通过回顾性HRMS数据分析对其他卤代羧酸的可疑筛查也表明存在其他碘化HAA和氯化丙酸,此处首次讨论了其中的一种(即一氯丙酸)。最重要的是,仅通过HRMS数据分析就可以排除一些潜在的嫌疑人。据我们所知,这是首次报道了饮用水中卤代羧酸的回顾性IC-HRMS筛选。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号