首页> 外文OA文献 >Computerized fetal heart rate analysis, Doppler ultrasound and biophysical profile score in the prediction of acid-base status of growth-restricted fetuses
【2h】

Computerized fetal heart rate analysis, Doppler ultrasound and biophysical profile score in the prediction of acid-base status of growth-restricted fetuses

机译:计算机胎儿心率分析,多普勒超声和生物物理特征评分预测生长受限胎儿的酸碱状态

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Objective To investigate the performance of non-stress test (NST), computerized fetal heart rate analysis (cCTG), biophysical profile scoring (BPS) and arterial and venous Doppler ultrasound investigation in the prediction of acid-base status in fetal growth restriction. Methods Growth-restricted fetuses, defined by abdominal circumference 95(th) percentile, were tested by NST, cCTG, BPS, and UA, middle cerebral artery (MCA), ductus venosus (DV) and umbilical vein (UV) Doppler investigation. The short-term variation (STV) of the fetal heart rate was calculated using the Oxford Sonicaid 8002 cCTG system. Relationships between antenatal test results and cord artery pH <7.20 were investigated, using correlation, parametric and non-parametric tests. Results Fifty-six of 58 patients (96.6%) received complete assessment of all variables. All were delivered by pre-labor Cesarean section at a median gestational age of 30+6 weeks. The UA pulsatility index (PI) was negatively correlated with the cCTG STV (Pearson correlation -0.29, P <0.05). The DV PI was negatively correlated with the pH (Pearson correlation -0.30, P <0.02). The cCTG mean minute variation and pH were not significantly correlated (Pearson correlation 0.13, P = 0.34). UV pulsations identified the highest proportion of neonates with a low birth pH (9/17, 53%), the highest number of false positives among patients with an abnormal BPS, abnormal DV Doppler and a STV
机译:目的探讨无压力测试(NST),计算机胎儿心率分析(cCTG),生物物理轮廓评分(BPS)以及动脉和静脉多普勒超声检查在预测胎儿生长受限的酸碱状态方面的作用。方法采用NST,cCTG,BPS和UA,大脑中动脉(MCA),静脉导管(DV)和脐静脉(UV)多普勒检查对腹围95%的胎儿进行生长受限测试。使用牛津Sonicaid 8002 cCTG系统计算胎儿心率的短期变化(STV)。使用相关,参数和非参数测试研究了产前测试结果与脐动脉pH <7.20之间的关系。结果58例患者中有56例(96.6%)接受了所有变量的完整评估。所有这些均通过分娩前剖腹产分娩,中位胎龄为30 + 6周。 UA搏动指数(PI)与cCTG STV呈负相关(Pearson相关-0.29,P <0.05)。 DV PI与pH呈负相关(Pearson相关-0.30,P <0.02)。 cCTG平均分钟变化与pH值无显着相关性(Pearson相关性0.13,P = 0.34)。紫外线脉动确定了出生pH较低的新生儿比例最高(9 / 17,53%),BPS异常,DV多普勒异常和STV异常的患者中假阳性的发生率最高

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号