首页> 外文OA文献 >High-resolution T1 mapping of the brain at 3T with driven equilibrium single pulse observation of T1 with high-speed incorporation of RF field inhomogeneities (DESPOT1-HIFI)
【2h】

High-resolution T1 mapping of the brain at 3T with driven equilibrium single pulse observation of T1 with high-speed incorporation of RF field inhomogeneities (DESPOT1-HIFI)

机译:高速结合RF场不均匀性(DESPOT1-HIFI),通过驱动平衡T1单脉冲观察T1,对3T处的大脑进行高分辨率T1映射

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Purpose: To investigate an alternative approach to correct for flip angle inaccuracies in the driven equilibrium single pulse observation of T1 (DESPOT1) T1 mapping method. Materials and Methods: While DESPOT1 is a robust method for rapid whole-brain voxelwise mapping of the longitudinal relaxation time, the approach is inherently sensitive to inaccuracies in the transmitted flip angle, defined by the B1 field, which become more severe with increased field. Here we propose an extension of the DESPOT1 technique, involving the additional acquisition of an inversion-prepared SPGR image alongside the conventional multiangle DESPOT1 data. From these combined data both B1 and T1 may be determined with high accuracy and precision. The method is evaluated at 3T with phantom and in vivo imaging experiments, with derived T1 estimates compared with values calculated from multiple inversion time inversion recovery data. Results: The method provides robust correction of flip angle variations, with less than 5% error compared with reference values for T1 between 300 msec and 2500 msec. Conclusions: The described approach, dubbed DESPOT1-HIF1, permits whole-brain T1 mapping at 3T, with 1 mm(3) isotropic voxels, in a clinically feasible time (approximate to 10 minutes) with T1 accuracy greater than 5% and with high precision
机译:目的:研究一种替代方法,以纠正T1驱动平衡单脉冲观测(DESPOT1)T1映射方法中的翻转角误差。材料和方法:虽然DESPOT1是一种用于快速全脑体素纵向舒张时间映射的可靠方法,但该方法固有地对透射翻转角的不精确性敏感,该不精确性由B1场定义,随着场的增加而变得更加严重。在这里,我们提出了DESPOT1技术的扩展,其中包括与常规多角度DESPOT1数据一起额外获取反演准备的SPGR图像。根据这些组合数据,可以高精度和高精度地确定B1和T1。该方法在3T下通过幻像和体内成像实验进行评估,将推导的T1估计值与从多个反演时间反演恢复数据计算出的值进行比较。结果:该方法可对翻转角变化进行可靠的校正,与300毫秒至2500毫秒之间的T1参考值相比,误差小于5%。结论:所描述的方法称为DESPOT1-HIF1,可以在临床可行的时间内(约10分钟)以1mm(3)的各向同性体素在3T处进行全脑T1定位,T1准确度大于5%,且高精确

著录项

  • 作者

    Deoni, S C L;

  • 作者单位
  • 年度 2007
  • 总页数
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类

相似文献

  • 外文文献
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号