Concordance of Macular Pigment Measurement Using Customized Heterochromatic Flicker Photometry and Fundus Autofluorescence in Age-Related Macular Degeneration

机译:使用定制的异色闪烁光度法和眼底自发荧光在年龄相关性黄斑变性中测量黄斑色素的一致性

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

PURPOSE:We compared macular pigment (MP) measurements using customized heterochromatic flicker photometry (Macular Metrics Densitometer) and dual-wavelength fundus autofluorescence (Heidelberg Spectralis HRA + OCT MultiColor) in subjects with early age-related macular degeneration (AMD).METHODS:Macular pigment was measured in 117 subjects with early AMD (age, 44-88 years) using the Densitometer and Spectralis, as part of the Central Retinal Enrichment Supplementation Trial (CREST; ISRCTN13894787). Baseline and 6-month study visits data were used for the analyses. Agreement was investigated at four different retinal eccentricities, graphically and using indices of agreement, including Pearson correlation coefficient (precision), accuracy coefficient, and concordance correlation coefficient (ccc).RESULTS:Agreement was poor between the Densitometer and Spectralis at all eccentricities, at baseline (e.g., at 0.25° eccentricity, accuracy = 0.63, precision = 0.35, ccc = 0.22) and at 6 months (e.g., at 0.25° eccentricity, accuracy = 0.52, precision = 0.43, ccc = 0.22). Agreement between the two devices was significantly greater for males at 0.5° and 1.0° of eccentricity. At all eccentricities, agreement was unaffected by cataract grade.CONCLUSIONS:In subjects with early AMD, MP measurements obtained using the Densitometer and Spectralis are not statistically comparable and should not be used interchangeably in either the clinical or research setting. Despite this lack of agreement, statistically significant increases in MP, following 6 months of supplementation with macular carotenoids, were detected with each device, confirming that these devices are capable of measuring change in MP within subjects over time. (http://www.controlled-trials.com number, ISRCTN13894787.).
机译:目的:我们比较了使用定制的异色闪烁光度法(Macular Metrics Densitometer)和双波长眼底自发荧光(Heidelberg Spectralis HRA + OCT MultiColor)对与年龄相关的黄斑变性(AMD)受试者的黄斑色素(MP)测量。作为中央视网膜富集补充试验(CREST; ISRCTN13894787)的一部分,使用光密度计和Spectralis在117例早期AMD(44-88岁)受试者中测量了色素的含量。使用基线和6个月的研究访问数据进行分析。在四个不同的视网膜偏心率上,以图形方式并使用包括皮尔逊相关系数(精度),准确度系数和一致性相关系数(ccc)在内的一致性指标对一致性进行了研究。结果:在所有偏心率下,光密度计和频谱仪之间的一致性差基线(例如,在0.25°偏心率时,精度= 0.63,精度= 0.35,ccc = 0.22)和在6个月时(例如,在0.25°偏心率中,精度= 0.52,精度= 0.43,ccc = 0.22)。对于偏心度为0.5°和1.0°的雄性,两种器械之间的一致性明显更高。结论:在患有早期AMD的受试者中,使用Densitometer和Spectralis获得的MP测量值在统计学上不具有可比性,因此在临床或研究环境中均不应互换使用。尽管没有达成共识,但是在每种设备中检测到补充了黄斑类胡萝卜素6个月后MP的统计显着增加,证实了这些设备能够测量受试者体内MP随时间的变化。 (http://www.control-trials.com编号,ISRCTN13894787。)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号