首页> 外文OA文献 >Procedura per la valutazione dellu27emissione di campi EM da un apparato per ipetermia con componente diatermica a 434.0 MHz e verifica del rispetto degli standard
【2h】

Procedura per la valutazione dellu27emissione di campi EM da un apparato per ipetermia con componente diatermica a 434.0 MHz e verifica del rispetto degli standard

机译:评估在434.0 MHz处具有透热成分的体温过低装置的EM场发射的评估程序,并验证是否符合标准

摘要

The objective of this technical report is to establish a measurement procedure and/or measurement protocol in order to characterize the electromagnetic, electric and/or magnetic field sources at the workplaces, particularly in hospitals and in medical environmental. In this particular cases the exposure to electromagnetic fields involve workers, in-patients and their parents, and the devices and medical equipments. For the workers case we refer on the D.Lgs 81/2008 which acknowledges the European Directive 2004/40/EC on the minimum health and safety requirements regarding the exposure of workers to the risks arising from physical agents (electromagnetic fields). For the in-patients the risk-benefit evaluation for exposure to electromagnetic fields is to advantage of benefit, except particular situations. For the parents of the in-patients we apply the standard fixed by the italian law (DPCM 8 Luglio 2003 "Fissazione dei limiti di esposizione, dei valori di attenzione e degli obiettivi di qualit? per la protezione della popolazione dalle esposizioni a campi elettrici, magnetici ed elettromagnetici generati a frequenze comprese fra 100 kHz e 300 GHz") For the devices and the medical equipments we refer to the CEI EN 60601-1-2. The standard fixes the electromagnetic immunity limits to 10 V/m for life-supporting equipments and systems and to 3 V/m for no life-supporting equipments and systems An instrument device for hyperthermia (Delta, Easytech Srl) has been chose as case-study for test the proposed measurement procedure. This instrument device is used in medical environmental to treatment of the pathologies of the locomotor apparatus. Its operating frequency is in ISM band (433.05?434.79 MHz).
机译:该技术报告的目的是建立一种测量程序和/或测量协议,以表征工作场所(尤其是医院和医疗环境中)的电磁,电场和/或磁场源。在这种特殊情况下,电磁场的辐射涉及工作人员,住院病人及其父母,设备和医疗设备。对于工人的情况,我们参考D.Lgs 81/2008,该文件认可了欧洲指令2004/40 / EC的最低健康和安全要求,有关工人承受物理因素(电磁场)带来的风险的最低健康和安全要求。对于住院患者,除特殊情况外,电磁场暴露的风险效益评估是有益的。对于住院患者的父母,我们采用了意大利法律确定的标准(DPCM 8 Luglio 2003,“按质量分配的法定条件”,“按权利分配的原产地标准”,磁电频率范围为100 kHz e 300 GHz”)对于设备和医疗设备,请参阅CEI EN 60601-1-2。该标准将生命支持设备和系统的电磁抗扰度限值固定为10 V / m,对于没有生命支持设备和系统的电磁抗扰度限值固定为3 V / m。为满足以下条件,选择了用于高温治疗的仪器设备(Delta,Easytech Srl):研究测试建议的测量程序。该仪器装置在医学环境中用于治疗运动设备的病理。它的工作频率在ISM频段(433.05?434.79 MHz)中。

著录项

相似文献

  • 外文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号