Direct solid sampling is proposed for Pb determination in eye shadow and blush samples by high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GF AAS). A mixture of Pd(NO3)2 + Mg(NO3)2 was employed as chemical modifier, and aqueous calibration (0.25-2.5 ng Pb, r = 0.998) was obtained. Accuracy of the determination of Pb in eye shadow and blush samples by the proposed method was verified by line source graphite furnace AAS as a comparative technique employing digested samples. The results obtained by the two methods were in agreement at a 95% confidence level (paired t-test). The limit of quantification (dry mass) was 0.020 ng mg–1. The Pb content in the eye shadow and blush samples varied between 1.222 and 9.632 ng mg–1 and 0.362 and 28.091 ng mg–1, respectively.
机译:建议使用高分辨率连续谱源石墨炉原子吸收光谱法(HR-CS GF AAS)对眼影和腮红样品中的Pb进行直接固体采样测定。使用Pd(NO3)2 + Mg(NO3)2的混合物作为化学改性剂,并获得水校准溶液(0.25-2.5 ng Pb,r = 0.998)。通过线源石墨炉AAS作为使用消解样品的比较技术,验证了该方法测定眼影和腮红样品中Pb的准确性。两种方法获得的结果在95%的置信度上(配对t检验)一致。定量极限(干质量)为0.020 ng mg–1。眼影和腮红样品中的铅含量分别为1.222至9.632 ng mg-1和0.362至28.091 ng mg-1。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号