首页> 外文OA文献 >The accuracy of radiographic techniques used for vertical localization of mini-implants fixture placement
【2h】

The accuracy of radiographic techniques used for vertical localization of mini-implants fixture placement

机译:用于微型植入物固定装置垂直定位的射线照相技术的准确性

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

OBJECTIVE: Evaluate the effectiveness of image diagnosis methods used in the vertical location of sites elect to insert mini-implants. METHODS: The sample was composed of four patients, in which 32 inter-radicular sites were established in the subsequent area, for setting up mini-implants. These sites were represented by holes filled out with guta-percha in acetate moulder (PCg - contact point of dental crowns in the acetate moulder; PIg - point of insertion of the mini-implant in the acetate moulder). Periapical X-rays, interproximal and computerized tomographies of cone-beam, with the moulders positioned in mouth, were performed and the following points were taken into consideration: PC - radiodense image of the PCg point; PI - radiodense image of the PIg point; PCx - contact point among the determined dental crowns on the X-ray. Vertical measures used: gold-pattern from PCg to PIg; measure 1 - from PC to PI; and measure 2 - from PCx to PI. The measures were compared through descriptive analysis and test t of Student. RESULTS: For the measure 1, differences statistically significant were observed (4.1%), in relation to the gold-pattern, 25% and 100% of the appraised measures in the computerized tomographies, interproximal and periapical X-rays, respectively. For the measure 2, differences statistically significant were observed in relation to the gold-pattern (4.1%), 56.2% and 100% of the appraised measures in the computerized tomographies, interproximal and periapical X-rays, respectively CONCLUSIONS: The cone-beam computerized tomography was the most precise exam in the evaluation of the vertical position of the elect sites to install mini-implants; the interproximal X-ray can, with reservation, be also used; the periapical X-ray presented unsatisfactory results, being contraindicated for this purpose.
机译:目的:评估在选择插入微型植入物的垂直位置上使用的图像诊断方法的有效性。方法:该样本由四名患者组成,在随后的区域中建立了32个放射状间位点,以建立微型植入物。这些部位由在醋酸盐模具中充满固特异的孔表示(PCg-醋酸盐模具中牙冠的接触点; PIg-微型植入物在醋酸盐模具中的插入点)。进行根尖X射线检查,锥形束近端和计算机断层摄影,并将模具置于嘴中,并考虑以下几点:PC-PCg点的放射致密图像; PI-PIg点的放射密集图像; PCx-X射线上确定的牙冠之间的接触点。使用的垂直度量:从PCg到PIg的金色图案;措施1-从PC到PI;并测量2-从PCx到PI。通过描述性分析和学生t检验比较了这些措施。结果:对于量度1,在计算机X线断层摄影,近端间和根尖X线片中,相对于金型,在统计学上有显着差异(4.1%),分别为评估量的25%和100%。对于测量2,在计算机断层扫描,近端X线检查和根尖周X射线检查中,分别在金图案(4.1%),56.2%和100%的评估测量中观察到统计学上的显着性。结论:锥束在评估安装微型植入物的选址的垂直位置时,计算机断层扫描是最精确的检查;还可以保留地使用X线间X射线;根尖X射线检查结果不理想,因此是禁忌的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号