The platelet blood count in laboratorial routine provides to the clinician important information about the hemostasis of the patient. There are many techniques described, however the gold standard techniques realized in hemocytometer spent a lot of time, making this technique impracticable in great routines. This research had the intent to evaluate if the automatic veterinary blood counter QBC Vet Autoread (R), whose results get five minutes to be ready, is capable to offer a trustworthy platelet count number. To this end, were evaluated the correlations among three different forms of platelets count in dogs: count in automatic blood counter QBC Vet Autoread (R), estimative in blood smear and the gold standard method by manual count in hemocytometer. The viability and confidence use of automatic blood counters of the medicine veterinary routine. Seventeen dogs were chosen randomly way, in the medical and surgical routine of HOVET-USP. The analysis revel high correlation between the hemocytometer and the estimative in blood smear (r=0,875) and between the hemocytometer and automatic blood count by QBC Vet Autoread (R) (r=0,939). Conclude that the platelet blood cont by QBC Vet Autoread (R), in addition to be fast, it's more truthful when compared with estimative in blood smear, although the latter one also had elevated correlation. However, morphological analysis through the smears cannot be dismissed because none of the other two techniques evaluated have the ability to assess platelet morphological changes.
机译:实验室常规中的血小板血液计数为临床医生提供了有关患者止血的重要信息。描述了许多技术,但是在血细胞计数器中实现的金标准技术花费了很多时间,这使得该技术在常规程序中不可行。该研究旨在评估自动兽血计数器QBC Vet Autoread(R)(其结果需要准备五分钟)是否能够提供可信赖的血小板计数。为此,评价了犬的三种不同形式的血小板计数之间的相关性:自动血液计数器QBC Vet Autoread(R)中的计数,血液涂片中的估计值以及通过血球计数器中手动计数的金标准方法。兽医自动程序使用自动血液计数器的可行性和信心。在HOVET-USP的医学和外科手术中随机选择了17只狗。该分析揭示了血细胞计数器与血涂片估计值之间的高度相关性(r = 0,875)以及血细胞计数器与通过QBC Vet Autoread(R)进行的自动血液计数之间的高度相关性(r = 0,939)。结论是,QBC Vet Autoread(R)的血小板血液含量较快,与估计的血涂片相比更真实,尽管后者的血涂片相关性也较高。然而,由于所评估的其他两种技术都没有评估血小板形态变化的能力,因此不能排除通过涂片进行的形态分析。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号