首页> 外文OA文献 >Effect of ridge lap surface treatment and thermocycling on microtensile bond strength of acrylic teeth to denture base resins
【2h】

Effect of ridge lap surface treatment and thermocycling on microtensile bond strength of acrylic teeth to denture base resins

机译:脊搭接表面处理和热循环对丙烯酸牙与义齿基础树脂的微拉伸粘合强度的影响

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

This study evaluated the effect of denture base polymer type (heat- and microwave-polymerized), ridge lap surface treatment (with and without methyl methacrylate-MMA etching) and thermocycling on the microtensile bond strength (mTBS) of Biotone acrylic teeth. Flat-ground, ridge-lap surface of posterior artifcial teeth were bonded to cylinders of each denture base resin, resulting in the following groups (n=6): G1a - Clássico/with MMA etching; G1b - Clássico/without MMA etching; G2a - OndaCryl/with MMA etching; G2b - OndaCryl/without MMA etching. Rectangular bar specimens with a cross-sectional area of 1 mm 2 were prepared. Half of the bars in each group were thermocycled (5,000 cycles between 4°C and 60°C). mTBS testing was performed in an universal testing machine at a crosshead speed of 0.5 mm/min. Data were analyzed statistically by three-way ANOVA (a=0.05). There was no statisti-caly signifcant difference (p>0.05) for the factors (resin, surface treatment,and thermocycling) or their interactions. The mean mTBS values (MPa) and standard deviations were as follows: Thermocycling - G1a: 41.00 (14.00); G1b: 31.00 (17.00); G2a: 50.00 (27.00); G2b: 40.00 (18.00); No thermocycling - G1a: 37.00 (14.00); G1b: 43.00 (25.00); G2a: 43.00 (14.00); G2b: 40.00 (27.00). The mTBS of Biotone artifcial teeth to the denture base acrylic resins was not infuenced by the polymer type, surface treatment or thermocycling.
机译:这项研究评估了义齿基础聚合物类型(热聚合和微波聚合),脊搭接表面处理(有或没有甲基丙烯酸甲酯-MMA蚀刻)和热循环对Biotone丙烯酸牙微拉伸粘合强度(mTBS)的影响。将后牙的平坦,隆起的表面粘合到每种义齿基础树脂的圆柱体上,得到以下组(n = 6):G1a-Clássico/ MMA蚀刻; G1b-Clássico/无MMA蚀刻; G2a-OndaCryl /具有MMA蚀刻功能; G2b-OndaCryl /无MMA蚀刻。制备横截面为1 mm 2的矩形钢筋样品。每组中的一半试条进行热循环(在4°C至60°C之间进行5,000个循环)。 mTBS测试在万能测试机中以0.5 mm / min的十字头速度进行。数据通过三因素方差分析进行统计学分析(a = 0.05)。这些因素(树脂,表面处理和热循环)或其相互作用均无统计学意义(p> 0.05)。平均mTBS值(MPa)和标准偏差如下:热循环-Gla:41.00(14.00); G1b:31.00(17.00); G2a:50.00(27.00); G2b:40.00(18.00);无热循环-G1a:37.00(14.00); G1b:43.00(25.00); G2a:43.00(14.00); G2b:40.00(27.00)。 Biotone人造牙与义齿基丙烯酸树脂的mTBS不受聚合物类型,表面处理或热循环的影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号