首页> 外文OA文献 >Evaluation of shear wave speed measurements using crawling waves sonoelastography and single tracking location acoustic radiation force impulse imaging
【2h】

Evaluation of shear wave speed measurements using crawling waves sonoelastography and single tracking location acoustic radiation force impulse imaging

机译:使用爬行波超声弹性成像和单跟踪位置声辐射力脉冲成像评估剪切波速度测量

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Many pathological conditions are closely related with an increase in tissue sti ness.For many years, experts performed manual palpation in order to measure elasticity changes, however, this method can only be applied on superficial areas of the human body and provides crude sti ness estimation. Elastography is a technique that attempts to characterize the elastic properties of tissue in order to provide additional and useful information for clinical diagnosis. For more than twenty years, di erent research groups have developed various elastography modalities with a strong interest for quantitative images during the last decade.Recently, comparative studies among di erent elastographic techniques have been performed in order to better characterize biomaterials, to cross-validate several shear wave elastographic modalities and to study the factors that influence their precision and accuracy.This comparison works may contribute to achieve standardization in quantitative elastography and their use in commercial equipment for their application in human patients. However, there is still a limited literature in the field of quantitative elastography modalities comparisons.This thesis focuses on the comparison between two elastographic techniques: crawlingwave sonoelastography (CWS) and single tracking location-acoustic radiation force impulse (STL-ARFI). The comparison shows the estimation of the shear wave speed (SWS), lateral resolution, contrast and contrast-to-noise ratio (CNR) in homogeneous and inhomogeneous phantoms using both techniques. The SWS values obtained with both modalities are validated with mechanical measurements that are considered as ground truth. The SWS results for the three di erent homogeneous phantoms (10%, 13%, and 16% gelatin concentrations), show good agreement between CWS, STL-ARFI and mechanical measurements as a function of frequency. The maximum accuracy errors obtained with CWS were 2.52%, 1.63% and 2.26%. For STL-ARFI, the maximum errors were 6.22%, 5.63% and 4.08% for the 10%,13% and 16% gelatin phantom respectively. For lateral resolution, contrast and CNR estimated in the inhomogeneous phantoms, it can be seen that for vibration frequencies higher than 340 Hz, CWS presents better results than the obtained with STL-ARFI using distances between the push beams ( x) higher than 4 mm. However, using these vibration frequencies will not be feasible for in vivo tissues due to attenuation problems. It that sense, for lower vibration frequencies than 300 Hz and x among 3 mm and 6 mm, comparable lateral resolution, contrast and CNR was obtained. Finally, the results of this study contribute to the data currently available for comparing elastographic techniques. Moreover, the methodology implemented in this document may be helpful for future standardizationfor di erent elastographic modalities.
机译:许多病理状况与组织张力的增加密切相关。多年以来,专家进行了手动触诊以测量弹性变化,但是这种方法仅适用于人体的浅表区域,并且可以提供粗略的张力估计。弹性成像是一种试图表征组织的弹性特性以便为临床诊断提供更多有用信息的技术。在过去的20多年中,不同的研究小组开发了各种弹性成像方法,对过去十年中的定量图像表现出了浓厚的兴趣。最近,为了更好地表征生物材料并交叉验证,进行了各种弹性成像技术之间的比较研究。几种剪切波弹性成像方式,并研究影响其精度和准确性的因素。这项比较工作可能有助于实现定量弹性成像的标准化及其在人类患者中的商业应用。然而,在定量弹性成像模态比较领域中,文献还很有限。本文着眼于两种弹性成像技术的比较:爬行波超声弹性成像(CWS)和单跟踪位置声辐射力脉冲(STL-ARFI)。比较显示了使用这两种技术对均质和不均质体模中的剪切波速度(SWS),横向分辨率,对比度和对比度-噪声比(CNR)的估计。两种方式获得的SWS值均通过被视为地面真实情况的机械测量值进行了验证。三种不同的均质体模(明胶浓度分别为10%,13%和16%)的SWS结果表明CWS,STL-ARFI和机械测量之间的良好一致性是频率的函数。通过CWS获得的最大精度误差为2.52%,1.63%和2.26%。对于STL-ARFI,10%,13%和16%的明胶模型的最大误差分别为6.22%,5.63%和4.08%。对于不均匀模型中的横向分辨率,对比度和CNR估计,可以看出,对于振动频率高于340 Hz的情况,CWS的效果要好于使用推力梁之间的距离(x)大于4 mm的STL-ARFI所获得的结果。 。然而,由于衰减问题,使用这些振动频率对于体内组织将是不可行的。从这个意义上说,对于3mm和6mm之间低于300Hz和x的振动频率,可以获得相当的横向分辨率,对比度和CNR。最后,这项研究的结果有助于目前可用于比较弹性成像技术的数据。此外,本文档中实施的方法可能有助于将来针对各种弹性成像模式进行标准化。

著录项

  • 作者

    Ormachea Quispe Juvenal;

  • 作者单位
  • 年度 2015
  • 总页数
  • 原文格式 PDF
  • 正文语种 spa
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号