首页> 外文OA文献 >Passive extraction and clean-up of phenoxy acid herbicides in samples from a groundwater plume using hollow fiber supported liquid membranes
【2h】

Passive extraction and clean-up of phenoxy acid herbicides in samples from a groundwater plume using hollow fiber supported liquid membranes

机译:使用中空纤维支持的液膜被动提取和净化地下水羽流中样品中的苯氧酸类除草剂

摘要

Hollow fiber supported liquid membranes were applied for the passive extraction of phenoxy acid herbicides from water samples. Polypropylene hollow fiber membranes (240 mu m i.d., 30 mu m wall thickness, 0.05 mu m pore size, 30 cm length) were impregnated with 2.0% tri-n-octylphosphine oxide (TOPO) in di-n-hexyl ether in the pores of the fiber wall to form a liquid membrane. They were then filled with basic solution in the lumen as acceptor and finally placed into the sample (donor). Complete extraction of phenoxy acid herbicides including 2,4-D, MCPA, dichlorprop, and mecoprop from an acidified sample (4 mL, adjusted to pH 1.5 with HCl) into basic acceptor (10 mu L of 0.2 M NaOH) was achieved after 4 h of shaking (100 rpm) resulting in an enrichment factor of 400 times. The acceptor was then neutralized by addition of HCl and injected into a HPLC system for the determination of the phenoxy acid herbicides. Environmentally relevant salinity (0-3.5% NaCl) and dissolved organic matter (0-25 mg/L of dissolved organic carbon) had no significant effect on the extraction. The method provided extraction efficiencies of more than 91%, detection limits of 0.3-0.6 mu g/L, and combined extraction and clean up in one single step. This procedure was applied to deter-mine aqueous concentrations of phenoxy acid herbicides in groundwater samples collected from an old dumping site (Cheminova, Denmark) with detected concentrations up to 5800 mu g/L. Although the samples were very dirty with large amounts of suspended particles, non-aqueous phase liquids (NAPLs) and dissolved organic matters, good spike recoveries (80-126%) were obtained for 10 of the 11 samples. (c) 2007 Elsevier B.V. All rights reserved.
机译:中空纤维支撑的液膜用于从水样中被动提取苯氧基酸类除草剂。聚丙烯中空纤维膜(内径240微米,壁厚30微米,孔径0.05微米,长度30厘米)在孔中的二正己基醚中浸渍有2.0%的三正辛基氧化膦(TOPO)。纤维壁的一部分形成液体膜。然后在管腔中将碱性溶液填充为受体,最后放入样品(供体)中。 4次后,将酸化样品(4 mL,用HCl调节至pH 1.5)中的苯氧基酸除草剂(包括2,4-D,MCPA,二氯丙醇和甲丙醇)完全萃取到碱性受体(10μL的0.2 M NaOH)中h的振动(100 rpm),产生400倍的富集系数。然后通过加入HCl中和受体,并将其注入HPLC系统中以确定苯氧基酸除草剂。与环境有关的盐度(0-3.5%NaCl)和溶解的有机物(0-25 mg / L的溶解有机碳)对萃取没有显着影响。该方法的萃取效率超过91%,检出限为0.3-0.6μg / L,并且萃取和净化相结合仅一步即可。该程序用于测定从旧的倾倒场(丹麦Cheminova)收集的地下水样品中苯氧基酸除草剂的水溶液浓度,检测到的浓度高达5800μg / L。尽管样品很脏,有大量的悬浮颗粒,非水相液体(NAPL)和溶解的有机物,但11个样品中的10个获得了良好的加标回收率(80-126%)。 (c)2007 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号