首页> 外文OA文献 >Determination of sulfonamide compounds in sewage and river by mixed hemimicelles solid-phase extraction prior to liquid chromatography-spectrophotometry
【2h】

Determination of sulfonamide compounds in sewage and river by mixed hemimicelles solid-phase extraction prior to liquid chromatography-spectrophotometry

机译:混合半胶体固相萃取-液相色谱-分光光度法测定污水和河流中的磺胺类化合物

摘要

Mixed hemimicelles-based solid-phase extraction was investigated for the preconcentration of five sulfonamides from environmental water samples prior to HPLC-spectrophotometry determination in this paper. A comparative study on the use of sodium dodecyl sulfate (SDS) coating gamma-alumina or octadecyltrimethylammonium bromide (OTMABr) and OTMABr coating silica as sorbent materials were presented. The five analytes (sulfadiazine (SDA), sulfathiazole (STA), sulfapyridine (SPD), sulfamethazine (SMZ) and sulfamethoxazole (SMX)) were quantitatively adsorbed on OTMABr-gamma-alumina and OTMABr-silica mixed hemimicelles, but OTMABr-gamma-alumina was not adopted because it worked at a high pH (around 10), instead, OTMABr-silica was selected to overcoming the pH restriction. The analytes retained on the cartridge were quantitatively desorbed with suitable amounts of methanol. Factors influencing the extraction efficiency, such as the amount of surfactant, pH of sample and breakthrough volume were discussed. The proposed method had been applied to determining the five sulfonamides in several environmental water samples and concentration factors of 300 and 600 for SDA and other four analytes were achieved, respectively. Detection limits obtained ranged between 0.15 and 0.35 mu g/L for this five sulfonamides under the optimized conditions. The accuracy of the method was evaluated by recovery measurements on spiked samples, and good recovery results (89-113%) with precision of 3-6% were achieved. (c) 2006 Elsevier B.V. All rights reserved.
机译:在进行HPLC分光光度法测定之前,研究了基于混合半胶束的固相萃取对环境水中样品中五种磺酰胺的预浓缩。提出了使用十二烷基硫酸钠(SDS)涂层γ-氧化铝或十八烷基三甲基溴化铵(OTMABr)和OTMABr涂层二氧化硅作为吸附剂材料的对比研究。五种分析物(磺胺嘧啶(SDA),磺胺噻唑(STA),磺胺吡啶(SPD),磺胺二甲基嘧啶(SMZ)和磺胺甲恶唑(SMX))被定量吸附在OTMABr-γ-氧化铝和OTMABr-二氧化硅混合半胶束上,但OTMABr-γ-未采用氧化铝,因为它可在高pH(约10)下工作,相反,选择OTMABr-二氧化硅克服了pH限制。保留在柱上的分析物用适量的甲醇定量解吸。讨论了影响萃取效率的因素,例如表面活性剂的量,样品的pH值和突破体积。该方法已用于测定几种环境水样中的五种磺酰胺类,并实现了SDA和其他四种分析物的浓缩系数分别为300和600。在优化条件下,这五种磺酰胺的检测限为0.15至0.35μg / L。通过对加标样品进行回收率测量来评估该方法的准确性,并获得了3%至6%的精密度的良好回收率结果(89-113%)。 (c)2006 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号