首页> 外文OA文献 >Multi-walled carbon nanotubes packed cartridge for the solid-phase extraction of several phthalate esters from water samples and their determination by high performance liquid chromatography
【2h】

Multi-walled carbon nanotubes packed cartridge for the solid-phase extraction of several phthalate esters from water samples and their determination by high performance liquid chromatography

机译:多壁碳纳米管填充柱,用于从水样品中固相萃取几种邻苯二甲酸酯并通过高效液相色谱法测定

摘要

Being suspected to have carcinogenic and estrogenic properties, the determination of phthalate esters in various environmental samples is very important for environmental risk assessment. In the present paper, a new solid-phase extraction system for HPLC determination of di-ethyl-phthalate, di-n-propyl-phthalate, di-iso-butyl-phthalate, and di-cyclohexyl-phthalate was developed. The four analytes were quantitatively adsorbed on multi-walled carbon nanotubes packed cartridge, then the analytes were quantitatively desorbed with acetonitrile, finally the analytes in acetonitrile eluate were determined by HPLC. Parameters influencing the extraction efficiency such as volume of sample solutions and eluent volume, were examined. Under the optimized conditions, detection limits of 0.18-0.86 ng ml(-1) were achieved for four phthalate esters. The proposed method had been used to determine the four phthalate esters in tap water, river water, and sea water samples. No phthalate esters were found in the river water and sea water samples. For the case of tap water sample, di-ethyl-phthalate, di-n-propyl-phthalate, and di-cyclohexyl-phthalate were not found, only 2.0 ng ml(-1) of di-iso-butyl-phthalate was found. The accuracy of the proposed method was tested by recovery measurements on spiked samples, the recoveries of 80.3-104.5% were obtained in most cases. (C) 2003 Elsevier B.V. All rights reserved.
机译:由于怀疑具有致癌和雌激素特性,各种环境样品中邻苯二甲酸酯的测定对环境风险评估非常重要。本文开发了一种新的固相萃取系统,用于HPLC测定邻苯二甲酸二乙酯,邻苯二甲酸二正丙酯,邻苯二甲酸二异丁酯和邻苯二甲酸二环己基酯。将四种分析物定量吸附在多壁碳纳米管填充柱上,然后用乙腈定量解吸,最后用HPLC测定乙腈洗脱液中的分析物。检查了影响萃取效率的参数,例如样品溶液的体积和洗脱液的体积。在优化的条件下,四种邻苯二甲酸酯的检出限达到0.18-0.86 ng ml(-1)。该提议的方法已用于测定自来水,河水和海水样品中的四种邻苯二甲酸酯。在河水和海水样品中未发现邻苯二甲酸酯。对于自来水样品,未发现邻苯二甲酸二乙酯,邻苯二甲酸二正丙酯和邻苯二甲酸二环己基酯,仅发现了2.0 ng ml(-1)的邻苯二甲酸二异丁酯。 。通过对加标样品进行回收率测试来检验所提方法的准确性,在大多数情况下,回收率达到80.3-104.5%。 (C)2003 Elsevier B.V.保留所有权利。

著录项

  • 作者

    Cai YQ; Jiang GB; Liu JF; Zhou QX;

  • 作者单位
  • 年度 2003
  • 总页数
  • 原文格式 PDF
  • 正文语种
  • 中图分类
  • 入库时间 2022-08-20 20:32:05

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号