A novel automated off-line preconcentration system for trace metals (Al, Mn, Fe, Co, Ni, Cu, Zn, Cd, and Pb) in seawater was developed by improving a commercially available solid-phase extraction system SPE-100 (Hiranuma Sangyo). The utilized chelating resin was NOBIAS Chelate-PA1 (Hitachi High-Technologies) with ethylenediaminetriacetic acid and iminodiacetic acid functional groups. Parts of the 8-way valve made of alumina and zirconia in the original SPE-100 system were replaced with parts made of polychlorotrifluoroethylene in order to reduce contamination of trace metals. The eluent pass was altered for the back flush elution of trace metals. We optimized the cleaning procedures for the chelating resin column and flow lines of the preconcentration system, and developed a preconcentration procedure, which required less labor and led to a superior performance compared to manual preconcentration (Sohrin et al.). The nine trace metals were simultaneously and quantitatively preconcentrated from ∼120 g of seawater, eluted with ∼15 g of 1M HNO3, and determined by HR-ICP-MS using the calibration curve method. The single-step preconcentration removed more than 99.998% of Na, K, Mg, Ca, and Sr from seawater. The procedural blanks and detection limits were lower than the lowest concentrations in seawater for Mn, Ni, Cu, and Pb, while they were as low as the lowest concentrations in seawater for Al, Fe, Co, Zn, and Cd. The accuracy and precision of this method were confirmed by the analysis of reference seawater samples (CASS-5, NASS-5, GEOTRACES GS, and GD) and seawater samples for vertical distribution in the western North Pacific Ocean.
机译:通过改进可商购的固相萃取系统SPE-100(Hiranuma),开发了一种用于海水中痕量金属(Al,Mn,Fe,Co,Ni,Cu,Zn,Cd和Pb)的新型自动化离线预浓缩系统三养)。所使用的螯合树脂是具有乙二胺三乙酸和亚氨基二乙酸官能团的NOBIAS Chelate-PA1(日立高科技)。在原来的SPE-100系统中,由氧化铝和氧化锆制成的8通阀的零件替换为由聚三氟氯乙烯制成的零件,以减少痕量金属的污染。改变洗脱液通过量以进行痕量金属的反冲洗。我们优化了预浓缩系统中螯合树脂塔和流水线的清洁程序,并开发了一种预浓缩程序,与手动预浓缩相比,它需要更少的劳动力并获得更好的性能(Sohrin等人)。从〜120 g海水中同时定量富集九种痕量金属,用〜15 g 1M HNO3洗脱,并通过HR-ICP-MS使用校准曲线方法进行测定。单步预浓缩从海水中去除了99.998%以上的Na,K,Mg,Ca和Sr。程序空白和检出限低于Mn,Ni,Cu和Pb的海水最低浓度,而低于Al,Fe,Co,Zn和Cd的海水最低浓度。通过分析参考海水样品(CASS-5,NASS-5,GEOTRACES GS和GD)以及在北太平洋西部垂直分布的海水样品,证实了该方法的准确性和精确性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号