首页> 外文OA文献 >The reliability and validity of a four-minute running time-trial in assessing VO2max and performance
【2h】

The reliability and validity of a four-minute running time-trial in assessing VO2max and performance

机译:四分钟运行时间评估VO2max和性能的可靠性和有效性

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。
获取外文期刊封面目录资料

摘要

Introduction: Traditional graded-exercise tests to volitional exhaustion (GXTs) are limited by the need to establish starting workloads, stage durations, and step increments. Short-duration time-trials (TTs) may be easier to implement and more ecologically valid in terms of real-world athletic events. The purpose of the current study was to assess the reliability and validity of maximal oxygen uptake (VO2max) and performance measured during a traditional GXT (STEP) and a four-minute running time-trial (RunTT). Methods: Ten recreational runners (age: 32 ± 7 years; body mass: 69 ± 10 kg) completed five STEP tests with a verification phase (VER) and five self-paced RunTTs on a treadmill. The order of the STEP/VER and RunTT trials was alternated and counter-balanced. Performance was measured as time to exhaustion (TTE) for STEP and VER and distance covered for RunTT. Results: The coefficient of variation (CV) for VO2max was similar between STEP, VER, and RunTT (1.9 ± 1.0, 2.2 ± 1.1, and 1.8 ± 0.8%, respectively), but varied for performance between the three types of test (4.5 ± 1.9, 9.7 ± 3.5, and 1.8 ± 0.7% for STEP, VER, and RunTT, respectively). Bland-Altman limits of agreement (bias ± 95%) showed VO2max to be 1.6 ± 3.6 mL·kg-1·min-1 higher for STEP vs. RunTT. Peak HR was also significantly higher during STEP compared with RunTT (P = 0.019). Conclusion: A four-minute running time-trial appears to provide more reliable performance data in comparison to an incremental test to exhaustion, but may underestimate VO2max.
机译:简介:传统的渐进式疲劳训练(GXT)受建立启动工作量,阶段持续时间和步长的限制。就真实世界的体育赛事而言,短时计时赛(TTs)可能更易于实施且在生态上更为有效。本研究的目的是评估在传统GXT(STEP)和四分钟跑步时间测试(RunTT)期间测得的最大摄氧量(VO2max)和性能的可靠性和有效性。方法:十名休闲跑步者(年龄:32±7岁;体重:69±10公斤)完成了五步带有验证阶段(VER)的STEP测试,以及五台跑步机上的自定速度RunTT。 STEP / VER和RunTT试验的顺序是交替进行和平衡的。以STEP和VER的疲惫时间(TTE)以及RunTT的覆盖距离来衡量性能。结果:STE2,VER和RunTT之间最大VO2max的变异系数(CV)相似(分别为1.9±1.0、2.2±1.1和1.8±0.8%),但在三种测试类型之间的性能差异较大(4.5对于STEP,VER和RunTT,分别为±1.9、9.7±3.5和1.8±0.7%)。 Bland-Altman一致性极限(偏差±95%)显示,STEP与RunTT相比,VO2max最高1.6±3.6 mL·kg-1·min-1。与RunTT相比,STEP期间的峰值HR也显着更高(P = 0.019)。结论:与进行疲劳测试相比,四分钟的运行时间测试似乎可以提供更可靠的性能数据,但可能会低估VO2max。

著录项

  • 作者

    McGawley, Kerry;

  • 作者单位
  • 年度 2017
  • 总页数
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号