Ultrasound evaluation in combination with finger extension force measurements of the forearm musculus extensor digitorum communis in healthy subjects

机译:超声评估结合手指伸展力测量健康受试者的前臂小指趾伸肌

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Background: The aim of this study was to evaluate the usefulness of an ultrasound-based method of examining extensor muscle architecture, especially the parameters important for force development. This paper presents the combination of two non-invasive methods for studying the extensor muscle architecture using ultrasound simultaneously with finger extension force measurements. Methods: M. extensor digitorum communis (EDC) was examined in 40 healthy subjects, 20 women and 20 men, aged 35-73 years. Ultrasound measurements were made in a relaxed position of the hand as well as in full contraction. Muscle cross-sectional area (CSA), pennation angle and contraction patterns were measured with ultrasound, and muscle volume and fascicle length were also estimated. Finger extension force was measured using a newly developed finger force measurement device. Results: The following muscle parameters were determined: CSA, circumference, thickness, pennation angles and changes in shape of the muscle CSA. The mean EDC volume in men was 28.3 cm3 and in women 16.6 cm3. The mean CSA was 2.54 cm2 for men and 1.84 cm2 for women. The mean pennation angle for men was 6.5° and for women 5.5°. The mean muscle thickness for men was 1.2 cm and for women 0.76 cm. The mean fascicle length for men was 7.3 cm and for women 5.0 cm. Significant differences were found between men and women regarding EDC volume (p < 0.001), CSA (p < 0.001), pennation angle (p < 0.05), muscle thickness (p < 0.001), fascicle length (p < 0.001) and finger force (p < 0.001). Changes in the shape of muscle architecture during contraction were more pronounced in men than women (p < 0.01). The mean finger extension force for men was 96.7 N and for women 39.6 N. Muscle parameters related to the extension force differed between men and women. For men the muscle volume and muscle CSA were related to extension force, while for women muscle thickness was related to the extension force. Conclusion: Ultrasound is a useful tool for studying muscle architectures in EDC. Muscle parameters of importance for force development were identified. Knowledge concerning the correlation between muscle dynamics and force is of importance for the development of new hand training programmes and rehabilitation after surgery. © 2008 Brorsson et al; licensee BioMed Central Ltd.
机译:背景:本研究的目的是评估一种基于超声的方法来检查伸肌结构,尤其是对于力发展重要的参数的有效性。本文介绍了两种无创方法的组合,用于同时使用超声和手指伸展力测量研究伸肌结构。方法:对40名健康受试者,20名女性和20名男性(年龄在35-73岁之间)进行了指趾伸肌(EDC)检查。在手的放松位置以及完全收缩状态下进行超声波测量。用超声波测量肌肉的横截面积(CSA),垂线角度和收缩方式,并估算肌肉的体积和束的长度。使用新开发的手指力测量装置测量手指伸展力。结果:确定了以下肌肉参数:CSA,周长,厚度,下垂角度和肌肉CSA形状的变化。男性平均EDC量为28.3 cm3,女性为16.6 cm3。男性的平均CSA为2.54 cm2,女性为1.84 cm2。男性的平均下垂角度为6.5°,女性的平均下垂角度为5.5°。男性的平均肌肉厚度为1.2厘米,女性为0.76厘米。男性的平均束长度为7.3 cm,女性的平均束长度为5.0 cm。男女在EDC量(p <0.001),CSA(p <0.001),下垂角(p <0.05),肌肉厚度(p <0.001),束长度(p <0.001)和手指力方面存在显着差异(p <0.001)。在收缩过程中,男性的肌肉结构形状变化比女性更明显(p <0.01)。男性的平均手指伸展力为96.7 N,女性的平均手指伸展力为39.6N。与伸展力相关的肌肉参数在男性和女性之间有所不同。对于男性,肌肉体积和肌肉CSA与伸展力有关,而对于女性,肌肉厚度与伸展力有关。结论:超声是研究EDC中肌肉结构的有用工具。确定了对于力量发展很重要的肌肉参数。有关肌肉动力学和力量之间关系的知识对于制定新的手部训练计划和术后康复至关重要。 ©2008 Brorsson等;被许可人BioMed Central Ltd.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号