Internal arcing test results of gapped Sic arresters are presented. During a test in which the arrester is exposed to internal arcing, the positive impulse breakdown voltage increases. Measurements made with a model arrangement indicate that the increase in the electrical strength of gas is higher for positive than for negative impulse polarity. When the internal discharges extinguish, recovery processes occur. Additional phenomena that can cause changes in the electrical strength are discussed.
机译:给出了带间隙的Sic避雷器的内部电弧测试结果。在避雷器暴露于内部电弧的测试过程中,正脉冲击穿电压会增加。用模型布置进行的测量表明,正极的气体电气强度的增加比负极性的脉冲极性的高。当内部放电熄灭时,就会发生恢复过程。讨论了可能导致电气强度变化的其他现象。