Commercial-off-the-shelf (COTS) capacitor-based isolation amplifiers were irradiated at the Portuguese Research Reactor (PRR) in order to determine its tolerance to the displacement damage and total ionising dose (TID). The set of experimental data shows that some of these devices are suitable for zones inside future nuclear facilities where the expected total radiation damage would be below 2.2 × 10 13 1 ‐ MeV neutron / cm 2 and 230 Gy (Si). However, some drawbacks must be taken into account by the electronic designers such as the increase of the output offset voltage and the slight modification of the transmission gain.
展开▼
机译:为了确定其对位移损伤和总电离剂量(TID)的耐受性,在葡萄牙研究堆(PRR)上照射了基于商用(COTS)电容器的隔离放大器。一组实验数据表明,这些装置中的某些装置适用于未来核设施内的区域,这些区域的预期总辐射损害将低于2.2×10 13 1 MeV中子/ cm 2和230 Gy(Si)。但是,电子设计人员必须考虑一些缺点,例如输出失调电压的增加和传输增益的轻微改变。
展开▼