首页> 外文OA文献 >Sealing and dentin bond strength of adhesive systems in selected areas of perfused teeth
【2h】

Sealing and dentin bond strength of adhesive systems in selected areas of perfused teeth

机译:牙胶在选定区域的密封性和牙本质粘合强度

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Objectives: (1) Test the sealing capacity and tensile strength of various adhesive systems: Scotch Bond 1 (Single Bond in USA)(SB1) + Z100, Syntac Sprint (SYN) + Tetric Ceram, Prime and Bond 2.1 (PB21) + TPH Spectrum, F2000 (Adhesive 1 Compomer) (F2000) and Optibond Solo (OPT) + Prodigy, to perfused teeth (30 cm distilled H2O), in select areas. (2) Determine the relationship between sealingudability and size of adhesive area (BA) with tensile strength (TS).udMethods: Segments of human third molars (n=67) sealed with amalgam on their coronal side were connected to a perfusion system (30 cm distilled H2O), to measure the basal permeability. Access cavities were drilled through the amalgam to expose dentin (area range: 8.7±20.8 mm2) and measure the permeability of that area. Cavities were sealed with one of the test materials and permeability measured prior to tensile testing. The percentage of decrease in permeability (PPD) that occurred with the different combinations of materials was also measured.udResults. Tensile strength: there were no statistically signi®cant differences among groups. Permeability: ANOVA showed that there were statistically signi®cant differences in the mean % decrease in permeability (PPD) among groups (p= 0:018): Student-Newman-Keuls test (p=0:05) detected that the mean PPD of F2000 ranked statistically higher than that of SB1. Relationship among variables: a linearudcorrelation was found defined by the formula TS= 7:47+ 0:008·PPD - 0:23·BA; with a significance of the model p=0.0097.udSignificance: None of the materials studied reduced permeability up to 100%. They all produced low tensile bond strengths (maximum mean value of groups: 5.51 MPa (OPT)).
机译:目标:(1)测试各种胶粘剂系统的密封能力和拉伸强度:Scotch Bond 1(美国Single Bond)(SB1)+ Z100,Syntac Sprint(SYN)+ Tetric Ceram,Prime and Bond 2.1(PB21)+ TPH Spectrum,F2000(粘合剂1复合剂)(F2000)和Optibond Solo(OPT)+ Prodigy,在选定区域中用于灌注牙齿(30厘米蒸馏水)。 (2)确定密封性/可粘合性与粘合区域大小(BA)与抗张强度(TS)之间的关系。 ud方法:将人类第三磨牙(n = 67)的部分在冠状侧用汞齐密封,进行灌注系统(30厘米蒸馏水),以测量基础渗透率。穿过汞合金钻出通孔,露出牙本质(面积范围:8.7±20.8 mm2)并测量该区域的渗透性。用一种测试材料密封空腔,并在拉伸测试之前测量渗透率。还测量了在不同材料组合下发生的磁导率降低(PPD)的百分比。 ud结果。拉伸强度:各组之间没有统计学上的显着差异。渗透性:方差分析表明,各组之间的渗透率平均降低百分比(PPD)在统计学上有显着差异(p = 0:018):Student-Newman-Keuls检验(p = 0:05)检测到平均PPD F2000的排名在统计上高于SB1。变量之间的关系:由公式TS = 7:47+ 0:008·PPD-0:23·BA定义为线性不相关;具有模型的显着性p = 0.0097。 ud意义:研究的所有材料均未将渗透率降低至100%。它们均产生较低的拉伸粘合强度(组的最大平均值:5.51 MPa(OPT))。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号