Pyrometer for measurement of surface temperature distribution on a rotating turbine blade

机译:高温计,用于测量旋转涡轮叶片上的表面温度分布

摘要

A conceptual optical method and some test results are presented for measuring the surface temperature distribution on one of the rotating turbine blades with a surface resolution of 0.05 cm spot diameter at a tip speed of 400 m/sec. The blade is scanned line-by-line by a fixed optical system. During each line-scan, the detector analog output signal is converted to two hundred consecutive digital values that are temporarily stored in a high speed buffer memory, and then transferred at a slower rate to a computer for processing. The signal-to-noise ratio of the silicon avalanche detector is large enough to obtain an accuracy of one percent at 1050 K blade temperature. By averaging 25 scans of the same line the same accuracy can be obtained at 900 K.
机译:提出了一种概念性的光学方法和一些测试结果,用于以400 m / sec的尖端速度测量表面直径为0.05 cm的旋转涡轮叶片之一上的表面温度分布。刀片由固定的光学系统逐行扫描。在每次线扫描期间,检测器模拟输出信号被转换为200个连续的数字值,这些数字值被临时存储在高速缓冲存储器中,然后以较低的速率传输到计算机进行处理。硅雪崩检测器的信噪比足够大,可以在1050 K刀片温度下获得1%的精度。通过对同一条线进行25次扫描平均,可以在900 K时获得相同的精度。