A new floating double-probe method is presented which has advantages over other floated-probe systems previously described in literature. The method utilized two electrodes, one of constant area and the other with a variable area. The two-electrode configuration is separated by a fixed bias voltage. The current-voltage characteristics of the new technique, which are generated by varying the area of the one electrode, are identical to those of a simple Langmuir probe, thus coupling all the advantages of a floated-probe system with the simple analysis scheme generally applied to the Langmuir probe for the determination of plasma density and temperature.
机译:提出了一种新的浮动双探针方法,该方法具有优于先前文献中描述的其他浮动探针系统的优势。该方法使用两个电极,一个电极的面积恒定,另一个电极的面积可变。两电极配置被固定的偏置电压隔开。通过改变一个电极的面积而产生的新技术的电流-电压特性与简单的朗缪尔探针的电流-电压特性相同,因此将浮动探针系统的所有优点与通常采用的简单分析方案结合在一起用Langmuir探针测定血浆密度和温度。