首页> 外文OA文献 >Construction and testing of a gas-loaded, passive-control, variable-conductance heat pipe
【2h】

Construction and testing of a gas-loaded, passive-control, variable-conductance heat pipe

机译:气体加载,被动控制,可变传导热管的建造和测试

摘要

A methanol heat pipe using nitrogen gas for temperature control has been constructed and tested. The system was run over a power ratio of 15 (2 to 30 watts) with the heat source near ambient temperature and with the heat sink at a nominal value of 32 F. Control was obtained with a metal bellows gas reservoir which was actuated by an internal liquid-filled bellows. The liquid bellows was pressurized by expanding liquid methanol which was contained in an auxiliary reservoir in the evaporator heater block. It was demonstrated that the temperature variation of the heat source was reduced from 36 F for the heat pipe with no control to 7 F with the actuated bellows control.
机译:已经构造并测试了使用氮气进行温度控制的甲醇热管。该系统在功率比为15(2到30瓦)的条件下运行,热源接近环境温度,散热器的标称值为32F。通过金属波纹管储气罐进行控制,该储气罐由一个金属波纹管驱动。内部充满液体的波纹管。通过使容纳在蒸发器加热块中辅助容器中的液态甲醇膨胀来对液体波纹管加压。结果表明,热源的温度变化从无控制的热管的36 F降低到波纹管控制的7F。