首页> 外文OA文献 >Visible and infrared linear detector arrays for the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS)
【2h】

Visible and infrared linear detector arrays for the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS)

机译:机载可见/红外成像光谱仪(AVIRIS)的可见和红外线性探测器阵列

摘要

The Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) instrument uses four separate focal plane assemblies consisting of line array detectors that are multiplexed to a common J-FET preamp using a FET switch multiplexing (MUX) technique. A 32-element silicon line array covers the spectral range from 0.41 to 0.70 microns. Three additional 64-element indium antimonide (InSb) line arrays cover the spectral range from 0.68 to 2.45 microns. The spectral sampling interval per detector element is nominally 9.8 nm, giving a total of 224 spectral channels. All focal planes operate at liquid nitrogen temperature and are housed in separate dewars. Electrical performance characteristics include a read noise of less than 1000 e(-) in all channels, response and dark nonuniformity of 5 percent peak to peak, and quantum efficiency of greater than 60 percent.
机译:机载可见/红外成像光谱仪(AVIRIS)仪器使用四个单独的焦平面组件,这些组件由线阵列检测器组成,这些线阵列检测器使用FET开关多路复用(MUX)技术多路复用到普通的J-FET前置放大器。一个32元素的硅线阵列覆盖从0.41到0.70微米的光谱范围。三个附加的64元素锑化铟(InSb)线阵列覆盖了0.68至2.45微米的光谱范围。每个探测器元件的光谱采样间隔标称值为9.8 nm,共有224个光谱通道。所有焦平面均在液氮温度下运行,并放置在单独的杜瓦瓶中。电气性能特征包括:所有通道的读取噪声均小于1000 e(-),峰峰值之间的响应和暗区不一致性为5%,量子效率大于60%。