Thermal conductance of augmented pressed metallic contacts at liquid helium temperatures

机译:液态氦温度下增强型压制金属触点的热导

摘要

The thermal conductance of uncoated oxygen-free high conductivity (OFHC) copper, 6061-T6 aluminum, free-machining brass, and 304 stainless steel sample pairs which were augmented with a gold coated 6061-T6 aluminum washer inserted between the contact surfaces was measured over the temperature range of 1.6 to 6.0 K, with applied forces from 22 to 670 N. The contact surfaces of the sample pairs were prepared with a 0.8 micron lapped finish, while the finish of the aluminum washer was 0.2 micron lapped. The contribution to the overall thermal impedance by the bulk conductance of the aluminum washer was negligible. It was found that addition of the washer offered no significant conductance improvement over an uncoated single contact pair; any benefits from using the gold plated washer were counteracted by the addition of two more contact surfaces. Additionally, the thermal conductance of a 'combination' aluminum sample pair having one gold coated and one uncoated surface was measured and compared to the washer pair. The ratio of the conductance of the washer pair to half the conductance of the 'combination' pair was found to be constant and near unity over the temperature range of the data obtained, within experimental error.
机译:测量了未镀层的无氧高电导率(OFHC)铜,6061-T6铝,自由加工的黄铜和304不锈钢样品对的热导率,这些样品对在接触面之间插入了涂有金的6061-T6铝垫圈在1.6到6.0 K的温度范围内,施加的力为22到670N。样品对的接触表面准备有0.8微米的研磨涂层,而铝垫圈的涂层是0.2微米的研磨涂层。铝垫圈的整体电导对总热阻的贡献可忽略不计。结果发现,与未涂覆的单触点对相比,添加垫圈并不能显着改善电导率。增加两个接触面抵消了使用镀金垫圈的任何好处。另外,测量了“组合”铝样品对的热导率,该样品对具有一个镀金表面和一个未镀膜表面,并与垫圈对进行了比较。发现垫圈对的电导率与“组合”对的电导率的一半之比在实验误差范围内是恒定的,并且在获得的数据的温度范围内接近统一。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号