首页> 外文OA文献 >Comparison of Ultrasound with Tensile Testing of Thermally Damaged Polyimide Insulated Wiring (MIL-W-81381)
【2h】

Comparison of Ultrasound with Tensile Testing of Thermally Damaged Polyimide Insulated Wiring (MIL-W-81381)

机译:超声与热损伤聚酰亚胺绝缘接线的拉伸测试的比较(MIL-W-81381)

摘要

Ultrasonic measurements were performed on MIL-W-81381/7, /12, and /21 wire, a polyimide (Kapton) insulated wire. The phase velocity for the 20-gauge MIL-W-81381/7 wire had a baseline value of 3023 plus or minus 78 m/s. After exposure to high temperatures, the wire's phase velocity rapidly increased, and reached an asymptotic value of 3598 plus or minus 20 m/s after 100 hours exposure. Similar responses were measured in other gauges. The baseline measurements of Young's moduli resulted in values of 5636 plus or minus 486, 7714 plus or minus 505, and 8767 plus or minus 292 KSI for the 20 ga, 16 ga, and 12 ga. wires respectively.
机译:超声波测量是在MIL-W-81381 / 7,/ 12和/ 21电线(聚酰亚胺(Kapton)绝缘电线)上进行的。 20规格的MIL-W-81381 / 7线的相速度的基线值为3023 +/- 78 m / s。暴露于高温后,焊丝的相速度迅速增加,并在暴露100小时后达到3598 +/- 20 m / s的渐近值。在其他量规中也测量了类似的响应。杨氏模量的基线测量结果分别为20 ga,16 ga和12 ga,分别为5636正负486、7714正负505和8767正负292 KSI。电线。