首页> 外文OA文献 >Liquid water content and droplet size calibration of the NASA Lewis Icing Research Tunnel
【2h】

Liquid water content and droplet size calibration of the NASA Lewis Icing Research Tunnel

机译:NASA刘易斯结冰研究隧道的液态水含量和液滴尺寸校准

摘要

The icing research tunnel at the NASA Lewis Research Center underwent a major rehabilitation in 1986 to 1987, necessitating recalibration of the icing cloud. The methods used in the recalibration, including the procedure used to establish a uniform icing cloud and the use of a standard icing blade technique for measurement of liquid water content are described. PMS Forward Scattering Spectrometer and Optical Array probes were used for measurement of droplet size. Examples of droplet size distributions are shown for several median volumetric diameters. Finally, the liquid water content/droplet size operating envelopes of the icing tunnel are shown for a range of airspeeds and are compared to the FAA icing certification criteria.
机译:美国宇航局刘易斯研究中心的结冰研究隧道在1986年至1987年进行了大规模修复,因此需要重新校准结冰云。描述了在重新校准中使用的方法,包括用于建立均匀的结冰云的过程以及使用标准的结冰刀片技术测量液态水含量的方法。使用PMS前向散射光谱仪和光学阵列探针测量液滴大小。显示了几个中等体积直径的液滴尺寸分布示例。最后,显示了在各种空速情况下结冰通道的液态水含量/液滴尺寸运行范围,并与FAA结冰认证标准进行了比较。

著录项

  • 作者

    Ide Robert F.;

  • 作者单位
  • 年度 1989
  • 总页数
  • 原文格式 PDF
  • 正文语种
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利