Measurement of the Band-to-Band Registration of the SNPP VIIRS Imaging System from On-Orbit Data

机译:从在轨数据测量SNPP VIIRS成像系统的带对带配准

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The Visible Infrared Imaging Radiometer Suite (VIIRS) instrument was launched 28 October 2011 onboard the Suomi National Polar-orbiting Partnership (SNPP) satellite. The VIIRS instrument is a whiskbroom system with 22 spectral and thermal bands split between 16 moderate resolution bands (M-bands), five imagery resolution bands (I-bands) and a day-night band. In this study we measure the along-scan and along-track band-to-band registration between the I-bands and M-bands from on-orbit data. This measurement is performed by computing the Normalized Mutual Information (NMI) between shifted image band pairs and finding the amount of shift required (if any) to produce the peak in NMI value. Subpixel accuracy is obtained by utilizing bicubic interpolation. Registration shifts are found to be similar to pre-launch measurements and stable (within measurement error) over the instruments first four years in orbit.
机译:可见红外成像辐射计套件(VIIRS)仪器于2011年10月28日在Suomi国家极地轨道合作伙伴(SNPP)卫星上发射。 VIIRS仪器是一个旋转扫帚系统,具有22个光谱和热波段,分为16个中分辨率波段(M波段),五个图像分辨率波段(I波段)和昼夜波段。在这项研究中,我们从轨道数据中测量了I波段和M波段之间的沿扫描和沿轨道的带间配准。通过计算偏移图像带对之间的归一化互信息(NMI)并找到产生NMI峰值所需的偏移量(如果有)来执行此测量。通过利用双三次插值获得子像素精度。发现配准偏移与发射前的测量相似,并且在轨道运行的头四年中稳定(在测量误差范围内)。