首页> 外文OA文献 >Mixing effectiveness test of an exhaust gas mixer in a high bypass turbofan at altitude
【2h】

Mixing effectiveness test of an exhaust gas mixer in a high bypass turbofan at altitude

机译:高旁路涡轮风扇高空排气混合器的混合效率测试

摘要

Thermal mixing effectiveness characteristics of an eighteen lobe, scalloped and unscalloped, partial, forced mixer were measured in a high-bypass turbofan engine. Data were also obtained without the mixer installed, i.e., free mixing. Tests were conducted at four combinations of simulated flight conditions from 0.3 to 0.8 Mach number and from 6,096 meters (20,000 ft) to 13,715 m (45,000 ft) altitude, mixing chamber lengths of L/D=0.52 and 0.65 were tested. For this range of test conditions and mixer configurations, the forced mixing effectiveness varied from 59 to 68 percent. Values of mixing effectiveness and total pressure loss were calculated from temperature and pressure data obtained at the mixer inlet and exhaust nozzle exit.
机译:在高旁路涡轮风扇发动机中测量了十八个扇形,扇形和非扇形,部分强制混合器的热混合效率特性。在没有安装混合器的情况下,即自由混合,也获得了数据。在模拟飞行条件的四种组合(从0.3到0.8马赫数)和从6,096米(20,000英尺)到13,715 m(45,000英尺)的高度下进行测试,测试了混合室长度L / D = 0.52和0.65。对于此范围的测试条件和混合器配置,强制混合效率从59%到68%不等。根据在混合器入口和排气喷嘴出口获得的温度和压力数据计算混合效率和总压力损失的值。