摘要

Following the Colombia accident, the Extravehicular Mobility Units (EMU) onboard ISS were unused for several months. Upon startup, the units experienced a failure in the coolant system. This failure resulted in the loss of Extravehicular Activity (EVA) capability from the US segment of ISS. With limited on-orbit evidence, a team of chemists, engineers, metallurgists, and microbiologists were able to identify the cause of the failure and develop recovery hardware and procedures. As a result of this work, the ISS crew regained the capability to perform EVAs from the US segment of the ISS.
机译:哥伦比亚事故发生后,国际空间站的机外机动部队(EMU)闲置了几个月。启动时,这些单元的冷却液系统出现故障。这次失败导致国际空间站美国分部失去了舱外活动(EVA)能力。在轨证据有限的情况下,由化学家,工程师,冶金学家和微生物学家组成的团队能够确定故障原因并开发恢复硬件和程序。这项工作的结果是,ISS机组恢复了执行ISS美国段EVA的能力。