External Tank Cable Tray vibration data for three successive Space Shuttle flights were analyzed to assess response to buffet and the effect of removal of the Protuberance Air Loads (PAL) ramp. Waveform integration, spectral analysis, cross-correlation analysis and wavelet analysis were employed to estimate vibration modes and temporal development of vibration motion from a sparse array of accelerometers and an on-board system that acquired 16 channels of data for approximately the first 2 min of each flight. The flight data indicated that PAL ramp removal had minimal effect on the fluctuating loads on the cable tray. The measured vibration frequencies and modes agreed well with predicted structural response.
机译:分析了连续三个航天飞机飞行的外部油罐电缆桥架振动数据,以评估对自助餐的响应以及去除突击空载(PAL)坡道的影响。波形积分,频谱分析,互相关分析和小波分析被用于从稀疏的加速度计阵列和车载系统中估计振动模式和振动运动的时间发展,该系统在大约前2分钟内获取了16个数据通道每个航班。飞行数据表明,移除PAL坡道对电缆桥架上波动的负载影响最小。测得的振动频率和模式与预测的结构响应非常吻合。